7P.26.9.420.1020 FINDER, 7P.26.9.420.1020 Datasheet - Page 9

SURGE ARRESTER, PV TYPE, 420VDC

7P.26.9.420.1020

Manufacturer Part Number
7P.26.9.420.1020
Description
SURGE ARRESTER, PV TYPE, 420VDC
Manufacturer
FINDER
Datasheet

Specifications of 7P.26.9.420.1020

Current Rating
100mA
Supply Voltage
420VDC
No. Of Poles
1
Mounting Type
DIN Rail
Rohs Compliant
Yes
Svhc
No SVHC (20-Jun-2011)
Ordering information
Replaceable modules
Example: 7P series, surge protection device, Type 2, single phase (Uc = 275 V), 1 varistor + 1 encapsulated spark gap, with remote status
Series
Type
0 = Combined type 1 + 2 arresters
1 = Type 1 surge arresters
2 = Type 2 surge arresters
3 = Type 3 surge arresters
Circuit
1 = Single phase (1 varistor)
2 = Single phase (1 varistor + 1 spark-gap)
3 = Three-phase (3 varistors)
4 = Three-phase (3 varistors + 1 spark-gap)
5 = Three-phase (4 varistors)
6 = 2 varistor + 1 spark-gap
9 = N-PE spark-gap
0 = Spare module
Supply version
1 = N+PE connection
8 = AC (50/60 Hz)
9 = DC (PV application)
Supply voltage
000 = 1.000 V DC Max (or N+PE connection for spark gap modules)
700 = 700 V DC Max
420 = 420 V DC Max
275 = 275 V Max for SPD Type 1 “Low Up”, Type 2 (U
260 = 260 V Max (U
255 = 255 V Max (U
(only for single spark gap replaceable module and 7P.09)
signalling contact, In = 20 kA
Replacement varistor and Spark-Gap modules
Maximum operating voltage (U
Impulse current (10/350 μs) (I
Nominal discharge current (8/20 μs) (I
Maximum discharge current (8/20 μs) (I
Voltage protection level (U
Response time (t
Maximum overcurrent protection
Replacement varistor and Spark-Gap modules 7P.20.8.275.0020 7P.20.9.350.0020 7P.20.9.500.0020 7P.20.1.000.0020 7P.20.1.000.9020
Maximum operating voltage (U
Nominal discharge current (8/20 μs) (I
Maximum discharge current (8/20 μs) (I
Voltage protection level (U
Response time (t
Maximum overcurrent protection
c
c
) for SPD Type 1+ 2 (for U
) for SPD Type 1, N+PE (7P.09)
7 P
a
a
)
)
.
P
P
2
)
)
C
imp
C
) V AC/DC
)
N
)
2
= 230-240 V AC)
max
max
V AC
n
n
) kA
) kA
) kA
) kA
.
kA
kV
kV
c
ns
ns
) (for U
8
160 A gL/gG
.
N
275 /—
Varistor
= 230-240 V AC) and Type 3
1.2
20
40
25
2 7 5
7P Series - Surge Protection Device (SPD)
7P.10.8.275.0012
160 A gL/gG
Varistor
160 A gL/gG
12.5
275
1.2
30
60
25
— / 350
Varistor
1.2
20
40
25
.
1
160 A gL/gG
0
— / 500
Varistor
1.8
20
40
25
Nominal discharge current
100 = 100 kA (I
012 = 12.5 kA (I
020 = 20 kA (I
025 = 25 kA (I
003 = 3 kA (In @ U
Remote status signalling contact
0 = Without remote status signalling contact
1 = Built-in remote status signalling contact
2 = Acoustic fault signalling
2
0
Spark-Gap
255 /—
7P.10.1.000.0025
n
imp
100
1.5
imp
20
40
Type 2)
imp
Spark-Gap
Type 1+2)
oc
Type 1) only for 7P.09
Type 1)
255
100
1.5
25
30
60
only for 7P.32)
Spark-Gap
— / 420
100
1.5
20
40
9