T3DDT0 GIC, T3DDT0 Datasheet - Page 26

TIME SWITCH, ASTRO, 3-PHASE CONTROL

T3DDT0

Manufacturer Part Number
T3DDT0
Description
TIME SWITCH, ASTRO, 3-PHASE CONTROL
Manufacturer
GIC
Datasheet

Specifications of T3DDT0

Contact Style
SPST
Contact Current Max
8A
Controller Output
Digital
Rohs Compliant
Yes
Digital Time Switches
• Precise time programming for Daily/Weekly/Pulse switching
• Simple Reset
• Weekend and Weekly OFF programming
• LED indication of Relay status
• 12/24 h display formats
• 6 years battery reserve
• Manual override
Cat. No.
Parameters
Supply Voltage & Frequency
Number of Modes &
it's description
Memory Locations
Minimum Switching Time
Power Consumption
Operating
Storage Temperature
Clock Accuracy
Power Reserve (Battery backup)
Switching Contact (Relay Output)
Shortest Switching Time
Contact Rating
Electrical Life
Contact Material
Mechanical Life
LED Indication
Housing
Dimension (W x H x D)
Weight
Mounting
Protection
Certification
EMI/ EMC
Radio Interference Suppression
ESD
Electrical Fast Transients
Surges
Voltage Dips & Interruptions
Applications
ORDERING INFORMATION
Cat. No.
67DDT0
67DDT9
Temperature
67DDT0 (
110 - 240 VAC, -20 %
Five
• AUTO
• ON AUTO
• AUTO OFF
• ON
• OFF
8 On / Off operations, 16 memory locations
1 m
6 VA (Approx)
-10°C to + 55°C
-10°C to + 60°C
± 1 s/day max. over the Operating Temperature range
6 Years running reserve
1 C/O (SPDT)
1 m (For Crono) & 1 s (For Pulse)
Resistive: - 16A @ 240 VAC / 28 VDC
Inductive (cos ø = 0.6) :- 6 A @ 250 VAC
Incandescent Lamp: - 1000 W
3x10
Ag Alloy
50 X 10
Red
Flame Retar nt UL94V0
36 X 65 X 90 (in mm)
12 g (unpacked)
Bas
IP
CISPR 14-1 Class B
IEC 61000-4-2 Level III
IEC 61000-4-4 Level IV
IEC 61000-4-5 Level IV
IEC 61000-4-5 Level III, Conducted Emission- IEC 61000-4-11 Class B
Ideal for Lighting applications like street lighting,
advertising displays. Also can be used for
Air conditioners / Coolers, Geysers, conveyors,
pumps etc.
Description
110 - 240 VAC (50/60 Hz), 1 C/O (SPDT)
110 - 240 VAC (50/60 Hz), 1 C/O (SPDT)
TIME & DAY SETTING:
Press RST key. Press
to set running hour & press M+key to set running Minute.
Mode - To set a mode press MAN key
PROGRAMMING:
To set a program - Press PRG key.
Set 1 ON time, day, then 1 OFF time, day
with the help of D+, H+ & M+ keys.
Like this we can set another 8 ON & 8 OFF programs.
20
0
e /
5
RoHS
DIN r il
Compliant
3
Re
lay ON
da
a
-
-
-
-
-
Program Run
Instant ON up to next ON Program
Instant OFF up to next OFF Program
Continuous ON
Continuous OFF
TM
&
+10%
key & keep it pressed. Then press D+ key to set running day. Press H+ key
TM
)
, 50 / 60 Hz
PROGRAMMING:
To set a program - Press PRG key.
(a) If pulse is common or the same, set pulse
before the ON time (b) If pulse time is different for
different programs, set the ON time first and then
set different pulse values for each programme
Three
• AUTO
• ON
• OFF
67DDT9 (
16 Pulse operations
(Ex - 0,1,2,3,4,5,6,7,8,9, a, b, c, d, e, f)
1 to 59 s Pulse Time (Same or Different)
Ideal for Siren, School bell application
-
-
-
Program Run
Continuous ON
Continuous OFF
)