TLE7235SE Infineon Technologies, TLE7235SE Datasheet - Page 23

no-image

TLE7235SE

Manufacturer Part Number
TLE7235SE
Description
IC DRIVER SPI RELAY CTRL DSO20
Manufacturer
Infineon Technologies
Series
-r
Type
High Side/Low Side Driverr
Datasheet

Specifications of TLE7235SE

Input Type
SPI
Number Of Outputs
8
On-state Resistance
850 mOhm, 1.6 Ohm
Current - Output / Channel
205mA, 410mA
Current - Peak Output
500mA, 1A
Voltage - Supply
9 V ~ 16 V
Operating Temperature
-40°C ~ 150°C
Mounting Type
Surface Mount
Package / Case
20-SOIC (0.295", 7.50mm Width)
Packages
PG-DSO-20
Channels
8.0
Rds (on) (typ)
0.85 Ohm
Vdd
3.0 - 5.5 V
Vds(cl)
41.0 - 52.0 V
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TLE7235SE
Manufacturer:
CONEXANT
Quantity:
437
8
The SPI of TLE7235SE provides diagnosis information about the device and about the load. The diagnosis
information of the protective functions of channel n is latched in the diagnosis flags Dn. It is cleared by the SPI
command CMD.CPL = 1. The CPL command clears itself with the next valid SPI communication frame.
The open load diagnosis of channel n is latched in the diagnosis flag OLn. This flag is cleared by reading the
according diagnosis register.
Following table shows possible failure modes and the according protective and diagnostic action.
Failure Mode
Open Load
Over Temperature
Over Load
(Short Circuit)
Data Sheet
Diagnostic Features
Diagnosis, when channel n is switched on: none
When over temperature occurs, the according diagnosis flag Dn is set. If the
Comment
Diagnosis, when channel n is switched off: according to voltage level at the
output pin, flag OLn is set after time
A diagnosis current can be enabled by SPI command DCCR.DCENn = 1.
affected channel n was active it is switched off.
The diagnosis flags are latched until they have been cleared by SPI
command CMD.CPL = 1.
When over load is detected at channel n, the affected channel is switched
off after time
The diagnosis flags are latched until they have been cleared by SPI
command CMD.CPL = 1.
t
OFF(OVL)
22
and the dedicated diagnosis flag Dn is set.
SPI Driver for Enhanced Relay Control
t
d(OL)
.
Diagnostic Features
Rev. 1.1, 2011-04-05
TLE7235SE

Related parts for TLE7235SE