D5C-1AA0 Omron, D5C-1AA0 Datasheet

no-image

D5C-1AA0

Manufacturer Part Number
D5C-1AA0
Description
Capacitive Touch Sensors AC W/ FREE ATTA CHMENT
Manufacturer
Omron
Series
D5Cr
Type
Capacitiver
Datasheet

Specifications of D5C-1AA0

Sensitivity
30 ~ 100pF
Response Time
8ms
Interface
-
Channel Inputs
1
Voltage - Supply
45 V ~ 264 V
Actuator Type
Free Attachment
Package / Case
18mm Dia Stainless Steel
Lead Free Status / Rohs Status
 Details
Unique 18-mm-dia. Capacitive Touch
Switch with Choice of Three Actuators is
Activated with Only a Very Slight
Physical Contact
• Only a slight activation force is required, enabling detecting micro
• Instantaneous operation upon contact with extremely limited
• Diameter of only 18 mm with standard built-in amplifier, operation
• Conforms to IEC IP67 *
• Freely replaceable antenna with screw mounting.
• Free attachment to enable changing the antenna shape according to
* Malfunction may occur if used in locations subject to water or oil.
Application Examples
Detection of Incorrectly Set Work
Detection of Fine Wire or Thin Plate
Detection of End of Cloth or Paper
(Detected with indirect ground)
The D5C detects the end of the paper or cloth
when the antenna touches ground.
deflections, thin wires, or thin-plate conductors (e.g., steel or
stainless).
Application possible for non-conductors by indirectly connecting to
ground.
hysteresis for high-precision position detection.
indicator, and sensitivity adjustment.
the application.
Touch Switch
D5C
D5C
D5C
Paper or cloth
Wire
Steel plate
Ground surface
Press
D5C
D5C
D5C
1.0 mm
Press Position Confirmation
Detection of Loose Screws
Detection of Seams in Cloth or Paper
(Detected with indirect ground)
The D5C detects the seam when the antenna
touches ground pole.
D5C
Paper or cloth
D5C
Press
D5C
Ground pole
Be sure to read Safety Precautions on page 6 to 7 and
Safety Precautions for All Limit Switches.
Detection of Bent Drills
Detection of Loose Wires
CSM_D5C_DS_E_2_1
D5C
D5C
1

Related parts for D5C-1AA0

D5C-1AA0 Summary of contents

Page 1

... Detection of Fine Wire or Thin Plate Wire D5C D5C Steel plate 1.0 mm Detection of End of Cloth or Paper (Detected with indirect ground) The D5C detects the end of the paper or cloth when the antenna touches ground. D5C Paper or cloth Ground surface Press Position Confirmation Press D5C ...

Page 2

... VAC (45 to 264 VAC), 50/60 Hz --- 50/60 Hz --- 2 mA max max max. 2,000 VAC, 50/60 Hz for 1 min between current-carry- ing metal parts and non-current-carrying metal parts 2 min. Approx. 120 g (in case of D5C-1AS0) D5C ·Any actuator can be attached. Free-attachment Model D5C-1DA0 D5C-1AA0 D5C-00A0 AC D5C-1A@0 --- 2 ...

Page 3

... Coil spring actuator (Stainless steel) O-ring Contactor Sensitivity adjuster O-ring Lead wire Washer Filled with glass epoxy Case Mounting nut ...the switching circuit operations, and an output signal is produced. Detection circuit NOT circuit ) ) 300 Caution label Use the specified voltage. Power supply D5C 3 ...

Page 4

... The D5C by itself can directly switch a load if DC power is provided. Connections Output Circuit Diagram The lead wire colors of the D5C have been changed in compliance with the latest applicable JIS standards. Colors in parentheses are previous ones. D5C-1D@0 (DC Model) Brown (Red) 4.7 kΩ ...

Page 5

... M4 × 0.7 *1 16.5 dia. Self-locking nut Two flat washers AC Models Coil Spring D5C-1AS0 Overtravel 16.5 dia. 6.5 dia. 1.2 dia. *1 Plunger D5C-1AP0 Overtravel 16.5 dia. Free-attachment D5C-1AA0 Lock nut M4 × 0.7 *1 16.5 dia. Self-locking nut Two flat washers (89) 61 (3,000 M18 × 1 ...

Page 6

... V is supplied. DC models cannot be connected in series. D5C D5C • Be sure to supply power to the D5C via the load. If power is supplied to the D5C directly, the fuse will blow. • If there are wire power lines or high-tension lines close to the cable of the D5C, be sure to wire the cable of the D5C away from power lines or high-tension lines or lay the cable in an exclusive, shielded conduit ...

Page 7

... Be sure to turn the adjuster with a torque of 0.08 N·m or less. If excessive torque is applied, the adjuster will break. Grounding • In order to maintain the operational reliability of the D5C, be sure to ground the blue or black wire of the power cable. • Operation may fail if the D5C is not grounded. ...

Page 8

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...

Related keywords