S29GL128N11FFIS33 Spansion Inc., S29GL128N11FFIS33 Datasheet - Page 61

no-image

S29GL128N11FFIS33

Manufacturer Part Number
S29GL128N11FFIS33
Description
Manufacturer
Spansion Inc.
Datasheet

Specifications of S29GL128N11FFIS33

Cell Type
NOR
Density
128Mb
Access Time (max)
110ns
Interface Type
Parallel
Boot Type
Not Required
Address Bus
24/23Bit
Operating Supply Voltage (typ)
3/3.3V
Operating Temp Range
-40C to 85C
Package Type
Fortified BGA
Sync/async
Asynchronous
Operating Temperature Classification
Industrial
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (max)
3.6V
Word Size
8/16Bit
Number Of Words
16M/8M
Supply Current
90mA
Mounting
Surface Mount
Pin Count
64
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
S29GL128N11FFIS33
Manufacturer:
SPANSION
Quantity:
5 000
Part Number:
S29GL128N11FFIS33
Manufacturer:
SPANSION
Quantity:
20 000
Legend
X = Don’t care.
RA = Address of the memory location to be read.
SA = Sector Address. Any address that falls within a specified sector. See Tables
PWA = Password Address. Address bits A1 and A0 are used to select each 16-bit portion of the 64-bit entity.
PWD = Password Data.
RD(0) = DQ0 protection indicator bit. If protected, DQ0 = 0. If unprotected, DQ0 = 1.
Notes
1. All values are in hexadecimal.
2. Shaded cells indicate read cycles.
3. Address and data bits not specified in table, legend, or notes are don’t cares (each hex digit implies 4 bits of data).
4. Writing incorrect address and data values or writing them in the improper sequence may place the device in an unknown state. The system must write the reset
5. Entry commands are required to enter a specific mode to enable instructions only available within that mode.
6. No unlock or command cycles required when bank is reading array data.
7. Exit command must be issued to reset the device into read mode; device may otherwise be placed in an unknown state.
8. Entire two bus-cycle sequence must be entered for each portion of the password.
9. Full address range is required for reading password.
10. Password may be unlocked or read in any order. Unlocking requires the full password (all seven cycles).
11. ACC must be at V
12. “All PPB Erase” command pre-programs all PPBs before erasure to prevent over-erasure.
May 30, 2008 S29GL-N_00_B8
Volatile Sector
Volatile Sector
Non-Volatile
(PPB Lock)
command to return the device to reading array data.
Protection
Protection
Protection
Protection
Password
Register
Freeze
Sector
Global
(PPB)
(DYB)
Lock
Bits
Command Sequence
Command Set Entry
Program
Read
Command Set Exit
Command Set Entry
Program
Read
Unlock
Command Set Exit
Command Set Entry
PPB Program
All PPB Erase (11, 12)
PPB Status Read
Command Set Exit
Command Set Entry
PPB Lock Bit Set
PPB Lock Bit Status Read
Command Set Exit
Command Set Entry
DYB Set
DYB Clear
DYB Status Read
Command Set Exit
(Notes)
IH
when setting PPB or DYB.
(6)
(9)
(10)
(6)
(8)
(11)
(7)
(7)
(7)
(7)
(7)
(5)
(5)
(5)
(5)
(5)
3
2
1
2
3
2
4
7
2
3
2
2
1
2
3
2
1
2
3
2
2
1
2
Addr
XXX
XXX
Table 9.2 Sector Protection Commands (x16)
555
555
555
555
555
XX
XX
XX
XX
XX
XX
XX
XX
SA
XX
XX
XX
SA
XX
00
00
First
D a t a
RD(0)
RD(0)
RD(0)
PWD
Data
Data
AA
AA
AA
AA
AA
A0
A0
A0
A0
A0
A0
90
25
90
80
90
90
90
0
PWAx
Addr
XXX
2AA
2AA
2AA
2AA
2AA
S h e e t
XX
XX
SA
XX
XX
XX
SA
SA
XX
01
00
00
Second
S29GL-N
PWD1
PWDx
Data
Data
55
00
55
03
00
55
00
30
00
55
00
00
55
00
01
00
7.2–7.4
Addr
555
555
555
555
555
02
00
for sector address ranges.
Third
Bus Cycles (Notes 1–4)
PWD
PWD
Data
C0
40
60
50
E0
2
0
Addr
03
01
Fourth
PWD
PWD
Data
3
1
Add
02
r
Fifth
Data
PWD
2
Add
03
r
Sixth
PWD
Data
3
Add
00
Seventh
r
Dat
29
a
61

Related parts for S29GL128N11FFIS33