2966537 Phoenix Contact, 2966537 Datasheet - Page 2

no-image

2966537

Manufacturer Part Number
2966537
Description
DIN RAIL TERM BLOCK W/RELAY SPDT
Manufacturer
Phoenix Contact
Series
-r
Datasheet

Specifications of 2966537

Relay Type
General Purpose
Contact Form
SPDT (1 Form C)
Contact Rating (current)
6A
Switching Voltage
250VAC, 250VDC - Max
Coil Type
Non Latching
Coil Current
3.2mA
Coil Voltage
230VAC/DC
Turn On Voltage (max)
-
Turn Off Voltage (min)
-
Features
LED Indicator, PLC Terminal Block
Mounting Type
DIN Rail
Termination Style
Screwless Clamp
Contact Material
Silver Tin Oxide (AgSnO)
Operate Time
7ms
Release Time
15ms
Coil Power
-
Coil Resistance
-
Operating Temperature
-25°C ~ 55°C
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
PLC-RSP-230UC/21
2
101780_en_02
PLC INTERFACE With Screw Connection
Description
PLC INTERFACE With Multi-Layer Contact Relay, Universal Version
PLC INTERFACE, comprising PLC-BSC.../21
basic terminal block and plug-in miniature relay
(see INTERFACE catalog), for mounting on
PLC INTERFACE With Power Contact Relay, Universal Version
PLC INTERFACE, comprising PLC-BSC.../21
basic terminal block and plug-in miniature relay
(see INTERFACE catalog), for mounting on
PLC INTERFACE With Spring-Cage Connection
Description
PLC INTERFACE With Multi-Layer Contact Relay, Universal Version
PLC INTERFACE, comprising PLC-BSC.../21
basic terminal block and plug-in miniature relay
(see INTERFACE catalog), for mounting on
PLC INTERFACE With Power Contact Relay, Universal Version
PLC INTERFACE, comprising PLC-BSC.../21
basic terminal block and plug-in miniature relay
(see INTERFACE catalog), for mounting on
1
1
The PLC-ATP BK insulating plate must be installed for voltages greater than 250 V (L1, L2, L3) between the same terminal points on adjacent modules
(see "Accessories"). FBST 8-PLC... or FBST 500... is then used for potential bridging.
The PLC-ATP BK insulating plate must be installed for voltages greater than 250 V (L1, L2, L3) between the same terminal points on adjacent modules
(see "Accessories"). FBST 8-PLC... or FBST 500... is then used for potential bridging.
Ordering Data
With the 120 V and 230 V modules, an REL-MR-60DC/... 60 V relay is normally used due to the input circuit integrated in the basic terminal block.
For the protection of input and output, inductive loads must be dampened with an effective protective circuit.
3
3
3
3
230 V AC/220 V DC
230 V AC/220 V DC
230 V AC/220 V DC
230 V AC/220 V DC
120 V AC/110 V DC
120 V AC/110 V DC
120 V AC/110 V DC
120 V AC/110 V DC
24 V AC/DC
24 V AC/DC
24 V AC/DC
24 V AC/DC
12 V DC
24 V DC
48 V DC
60 V DC
12 V DC
24 V DC
48 V DC
60 V DC
12 V DC
24 V DC
48 V DC
60 V DC
12 V DC
24 V DC
48 V DC
60 V DC
1
1
1
1
Type
PLCRSC- 12DC/21AU
PLCRSC- 24DC/21AU
PLCRSC- 24UC/21AU
PLCRSC- 48DC/21AU
PLCRSC- 60DC/21AU
PLCRSC-120UC/21AU
PLCRSC-230UC/21AU
PLCRSC- 12DC/21
PLCRSC- 24DC/21
PLCRSC- 24UC/21
PLCRSC- 48DC/21
PLCRSC- 60DC/21
PLCRSC-120UC/21
PLCRSC-230UC/21
Type
PLCRSP- 12DC/21AU
PLCRSP- 24DC/21AU
PLCRSP- 24UC/21AU
PLCRSP- 48DC/21AU
PLCRSP- 60DC/21AU
PLCRSP-120UC/21AU
PLCRSP-230UC/21AU
PLCRSP- 12DC/21
PLCRSP- 24DC/21
PLCRSP- 24UC/21
PLCRSP- 48DC/21
PLCRSP- 60DC/21
PLCRSP-120UC/21
PLCRSP-230UC/21
Order No.
2966919
2966265
2966278
2966126
2966142
2966281
2966294
2966906
2966171
2966184
2966113
2966139
2966197
2966207
Order No.
2967442
2966540
2966553
2966566
2966579
2966582
2966647
2967439
2966472
2966485
2966498
2966511
2966524
2966537
PHOENIX CONTACT
Pcs./Pck.
10
10
10
10
10
10
10
10
10
10
10
10
10
10
Pcs./Pck.
10
10
10
10
10
10
10
10
10
10
10
10
10
10
PLC-RS…/21
2

Related parts for 2966537