1-145169-2 TE Connectivity, 1-145169-2 Datasheet - Page 5

DIN 41612 Connectors AMP .050C/L PCI 92 D 210

1-145169-2

Manufacturer Part Number
1-145169-2
Description
DIN 41612 Connectors AMP .050C/L PCI 92 D 210
Manufacturer
TE Connectivity
Datasheets

Specifications of 1-145169-2

Number Of Rows
2
Number Of Positions / Contacts
18
Contact Plating
Gold
Pcb Mounting Orientation
Vertical
Number Of Dual Positions
92
Pcb Mount Style
Through Hole
Holddown Material
Brass
Holddown Plating
Tin-Lead over Nickel
Voltage (vac)
5
Termination Post Length (mm [in])
3.56 [0.140]
Solder Tail Contact Plating
Tin-Lead over Nickel
Number Of Positions
184
Centerline (mm [in])
1.27 [0.050]
Bus Width
64 Bit
Pcb Mount Retention Type
Hold Down Post(s)
Ejector
Without
Number Of Holddowns
3
Family Name
PCI
Contact Plating, Mating Area, Material
Gold (30)
Contact Base Material
Phosphor Bronze
Housing Color
White
Housing Material
Thermoplastic - GF
Rohs/elv Compliance
Not ELV/RoHS compliant
Lead Free Solder Processes
Wave solder capable to 240°C, Wave solder capable to 260°C, Wave solder capable to 265°C
Lead Free Status / Rohs Status
No
4.
4.1.
4.2.
4.3.
4.4.
Rev D
QUALITY ASSURANCE PROVISIONS
Qualification Testing
A.
B.
Requalification Testing
If changes significantly affecting form , fit or function are m ade to product or m anufacturing process,
product assurance shall coordinate requalification testing, consisting of all or part of original testing
sequence as determ ined by developm ent/product, quality and reliability engineering.
Acceptance
Acceptance is based on verification that product m eets requirem ents of Figure 1. Failures attributed to
equipm ent, test setup or operator deficiencies shall not disqualify product. W hen product failure occurs,
corrective action shall be taken and sam ples resubm itted for qualification. Testing to confirm corrective
action is required before resubm ittal.
Quality Conform ance Inspection
Applicable quality inspection plan will specify sam pling acceptable quality level to be used. Dim ensional
and functional requirem ents shall be in accordance with applicable product drawing and this
specification.
Sam ple Selection
Sam ples shall be prepared in accordance with applicable Instruction Sheets and shall be selected
at random from current production. All test groups shall consist of 5 sam ples each.
Test Sequence
Qualification inspection shall be verified by testing sam ples as specified in Figure 2.
108-14034
5 of 6