170BNO67100 Crouzet USA, 170BNO67100 Datasheet - Page 7

18C2463

170BNO67100

Manufacturer Part Number
170BNO67100
Description
18C2463
Manufacturer
Crouzet USA
Datasheet

Specifications of 170BNO67100

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Rohs Compliant
No
Composition
Advantys
Solution
Open and Modular System
An Advantys STB island is made up of one or more segments comprising PDMs
(Power Distribution Modules) and input/output modules.
An Advantys STB island starts with a network interface module and ends with a bus
terminator supplied with this module.
An island can be made up of a single segment or a primary segment and up to 6
extension segments, chained by EOS (End Of Segment) and BOS (Beginning Of
Segment) extension modules.
On each segment:
b The PDMs (Power Distribution Modules) must be placed immediately to the right
of the network interface modules or extension modules.
b The I/O modules are placed to the right of the PDM module supplying them with
power.
b Every module, whether PDM or I/O, is held in a fixing base on the DIN rail. (1)
Three module and base widths are possible. On the DIN rail, the overall width needed
for a segment is the sum of widths of the network interface module, the bases and
any bus termination.
The bases ensure the continuity of the internal bus, the auto-addressing of the
modules and the separated and isolated distribution of the internal power supplies,
actuators and sensors.
The advantages of this arrangement are:
b Unplugging of modules:
v When switched off, all modules can be unplugged very quickly.
v When switched on (hot swap), I/O modules can be unplugged provided the
network interface module is of standard type.
b Output power supply independent of inputs:
For example, if an output power supply is cut by a Preventa
inputs are still managed.
b Immunity of inputs:
For example, the closing of power contactors (controlled by outputs) does not disturb
analog input measurements.
The NIM (Network Interface Module)
This module manages communications on the island bus. It acts as a gateway for
exchanges with the fieldbus or network master. 11 NIM models are offered for:
Ethernet TCP/IP (standard only), CANopen, Modbus Plus
(standard only), I
(1) Each module (apart from the NIM Network Interface Module) requires a base and one or more
Composition of an Advantys STB island
specific connectors.
NTER
B
US
®
, Profibus DP and DeviceNet networks.
STB Distributed I/O
(standard only), Fipio
safety module, the
7
®
0

Related parts for 170BNO67100