AT49LV080-12TC ATMEL Corporation, AT49LV080-12TC Datasheet
AT49LV080-12TC
Related parts for AT49LV080-12TC
AT49LV080-12TC Summary of contents
Page 1
... A17 A18 A19 I/ RDY/BUSY I/ I/O7 I/ I/O6 I/ I/O5 GND 21 24 I/O4 GND 22 23 VCC 8-Megabit ( Single 2.7-volt Battery-Voltage Flash Memory AT49BV080 AT49BV080T AT49LV080 AT49LV080T 0812A–8/97 ...
Page 2
Description (Continued) To allow for simple in-system reprogrammability, the AT49BV/LV080 does not require high input voltages for programming. 3-volt-only commands determine the read and programming operation of the device. Reading data out of the device is similar to reading from ...
Page 3
Device Operation (Continued) be performed. Please refer to the Command Definitions table. BOOT BLOCK LOCKOUT DETECTION: A software method is available to determine if programming of the boot block section is locked out. When the device is in the software ...
Page 4
Command Definition (in Hex) Bus 1st Bus Command Cycles Cycle Sequence Addr Data Read 1 Addr D OUT 6 5555 AA Chip Erase Byte 4 5555 AA Program Boot Block 6 5555 AA (1) Lockout Product ID 3 5555 AA ...
Page 5
DC and AC Operating Range Com. Operating Temperature (Case) Ind. V Power Supply CC Operating Modes Mode CE OE Read (2) Program Standby/Write ( Inhibit Program Inhibit X X ...
Page 6
AC Read Characteristics Symbol Parameter t Address to Output Delay ACC ( Output Delay CE ( Output Delay OE ( Output Float DF Output Hold from OE, CE ...
Page 7
AC Byte Load Characteristics Symbol Parameter Address, OE Set-up Time AS OES t Address Hold Time AH t Chip Select Set-up Time CS t Chip Select Hold Time CH t Write Pulse Width (WE or CE) WP ...
Page 8
Program Cycle Characteristics Symbol Parameter t Byte Programming Time BP t Address Set-up Time AS t Address Hold Time AH t Data Set-up Time DS t Data Hold Time DH t Write Pulse Width WP t Write Pulse Width High ...
Page 9
Data Polling Characteristics Symbol Parameter t Data Hold Time Hold Time OEH Output Delay OE t Write Recovery Time WR Notes: 1. These parameters are characterized and not 100% tested. 2. See t spec ...
Page 10
Software Product (1) Identification Entry LOAD DATA AA TO ADDRESS 5555 LOAD DATA 55 TO ADDRESS 2AAA LOAD DATA 90 TO ADDRESS 5555 ENTER PRODUCT IDENTIFICATION ( MODE Software Product (1) Identification Exit OR LOAD DATA AA TO ...
Page 11
Ordering Information t I (mA) ACC CC (ns) Active Standby 120 25 0.05 25 0.05 150 25 0.05 25 0.05 200 25 0.05 25 0.05 120 25 0.05 25 0.05 150 25 0.05 25 0.05 200 25 0.05 25 0.05 ...
Page 12
... AT49LV080-20TC 40T AT49LV080-20CI 42C2 AT49LV080-20RI 44R AT49LV080-20TI 40T AT49LV080T-12CC 42C2 AT49LV080T-12RC 44R AT48LV080T-12TC 40T AT49LV080T-12CI 42C2 AT49LV080T-12RI 44R AT49LV080T-12TI 40T AT49LV080T-15CC 42C2 AT49LV080T-15RC 44R AT49LV080T-15TC 40T AT49LV080T-15CI 42C2 AT49LV080T-15RI 44R AT49LV080T-15TI 40T AT49LV080T-20CC 42C2 AT49LV080T-20RC 44R AT49LV080T-20TC 40T AT49LV080T-20CI 42C2 AT49LV080T-20RI ...