Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature,
unless otherwise specified. All temperatures refer to the operating temperature at the center of the baseplate.
Note: For important information relative to applications where the converter modules are subject to continuous dynamic loading,
Parameter
Operating input voltage
Input surge withstand
Undervoltage turn-on
Undervoltage turn-off
Overvoltage turn-off/on
Disabled input current
Parameter
Output voltage setpoint
Line regulation
Temperature regulation
Power sharing accuracy
Programming range
+Out to –Out — Absolute Maximum Ratings
Parameter
Baseplate to sink; flat, greased surface
Baseplate to sink; thermal pad (P/N 20265)
Baseplate to ambient
Baseplate to ambient; 1000 LFM
Thermal capacity
MODULE INPUT SPECIFICATIONS
MODULE OUTPUT SPECIFICATIONS
THERMAL RESISTANCE AND CAPACITY
2 V
3.3 V
5 V
8 V
12 V
15 V
24 V
28 V
36 V
48 V
contact Vicor applications engineering at 800-927-9474.
Set your site on VICOR at vicorpower.com
204.7
429.2
Min
250
Min
10
±0.002
242.5
212.2
446.3
±0.02
Typ
375
Typ
±2
Min
-0.5 to 10.9
-0.5 to 16.1
-0.5 to 20.0
-0.5 to 31.7
-0.5 to 36.9
-0.5 to 47.1
-0.5 to 62.9
-0.5 to 3.1
-0.5 to 4.7
-0.5 to 7.0
±0.005
247.5
467.5
±0.20
Max
Max
425
500
110
1.1
± 5
±1
375V Micro Family
% Vout nom.
0.24
0.21
10.9
Typ
2.8
48
% / °C
Unit
Vdc
Vdc
Vdc
Vdc
Vdc
Unit
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
mA
%
%
%
Notes
<100 ms
PC pin low
Notes
Nominal input; full load; 25°C
Low line to high line; full load
Over operating temperature range
10 to 100% of full load
Of nominal output voltage. For trimming below 90%
of nominal, a minimum load of 10% of maximum
rated power may be required.
Externally Applied
Externally Applied
Externally Applied
Externally Applied
Externally Applied
Externally Applied
Externally Applied
Externally Applied
Externally Applied
Externally Applied
Max
Watt-sec/°C
°C/Watt
°C/Watt
°C/Watt
°C/Watt
Rev. 8.4
Unit
Page 2 of 13