Description
The JAHW050A, JAHW075A and JAHW100A Power Modules are dc-dc converters that operate over an input
voltage range of 36 Vdc to 75 Vdc and provide a precisely regulated dc output. The outputs are fully isolated
from the inputs, allowing versatile polarity configurations and grounding connections. The modules have maxi-
mum power ratings from 50 W to 100 W at a typical full-load efficiency of 90%.
The sealed modules offer a metal baseplate for excellent thermal performance. Threaded-through holes are pro-
vided to allow easy mounting or addition of a heat sink for high-temperature applications. The standard feature set
includes remote sensing, output trim, and remote on/off for convenient flexibility in distributed power applications.
* ISO is a registered trademark of the International Organization for Standardization.
† UL is a registered trademark of Underwriters Laboratories, Inc.
‡ CSA is a registered trademark of Canadian Standards Association.
§ VDE is a trademark of Verband Deutscher Elektrotechniker e.V.
** This product is intended for integration into end-use equipment. All the required procedures for CE marking of end-use equipment should be followed. (The CE mark is placed on
The JAHW Series Power Modules use advanced, surface-
mount technology and deliver high-quality, efficient, and
compact dc-dc conversion.
Applications
n
n
n
n
Options
n
n
selected products.)
Distributed power architectures
Workstations
Computer equipment
Communications equipment
Choice of remote on/off logic configuration
Latching protection features
dc-dc Converters; 36 to 75 Vdc Input, 5 Vdc Output; 50 to 100 W
JAHW050A, JAHW075A and JAHW100A Power Modules:
Features
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
Small size: 61.0 mm x 57.9 mm x 12.7 mm
High power density
High efficiency: 90% typical
Low output noise
Constant frequency
Industry-standard pinout
Metal baseplate
2:1 input voltage range
Overcurrent protection (hiccup mode)
Remote on/off
Adjustable output voltage
Remote sense
Output overvoltage protection (hiccup mode)
Overtemperature protection (hiccup mode)
Case ground pin
ISO* 9001 Certified manufacturing facilities
Meets the voltage and current requirements for
ETSI 300-132-2 and complies with and is Licensed
for Basic Insulation rating per EN60950 (-B version
only)
UL
Certified, and VDE
Licensed
CE mark meets 73/23/EEC and 93/68/EEC
directives
60950 Recognized, CSA
**
(2.40 in. x 2.28 in. x 0.50 in.)
§
0805 (IEC60950, IEC950)
22.2 No. 60950-00

Related parts for JAHW075A

JAHW075A Summary of contents

Page 1

... Description The JAHW050A, JAHW075A and JAHW100A Power Modules are dc-dc converters that operate over an input voltage range of 36 Vdc to 75 Vdc and provide a precisely regulated dc output. The outputs are fully isolated from the inputs, allowing versatile polarity configurations and grounding connections. The modules have maxi- mum power ratings from 100 typical full-load efficiency of 90% ...

Page 2

... max JAHW050A (See Figure 1.) JAHW075A (See Figure 2.) JAHW100A (See Figure 3.) Inrush Transient Input Reflected-ripple Current, Peak-to-peak ( MHz, 12 µH source impedance; see Figure 19.) Input Ripple Rejection (120 Hz) Fusing Considerations CAUTION: This power module is not internally fused. An input line fuse must always be used. ...

Page 3

... Lineage Power (continued) Device All All All All All All All All JAHW050A JAHW075A JAHW100A JAHW050A JAHW075A JAHW100A All = 70 °C) JAHW050A C JAHW075A JAHW100A All = 25 ° max All All : O, max All All μ μ F aluminum and 1 F ceramic. Symbol Min Typ Max V 4 ...

Page 4

... April 2008 Typ Max 2,000,000 hours — 100 (3.5) g (oz.) Min Typ Max 0 — 1.2 — — 1.0 — — 15 — — 50 — — — 0.5 60 — 110 %V 5.9* — 7.0* — 110 — C Lineage Power Unit Unit µ nom V °C ...

Page 5

... INPUT VOLTAGE, V Figure 1. Typical JAHW050A Input Characteristics at Room Temperature 3 2.5 2 1 INPUT VOLTAGE, V Figure 2. Typical JAHW075A Input Characteristics at Room Temperature Lineage Power 2.5 2 1 ...

Page 6

... (A) O 8-2076 (F) Note: See Figure 20 for test conditions. Figure 7. Typical JAHW050A Output Ripple Voltage = (A) O 1-0463 Note: See Figure 20 for test conditions. Figure 8. Typical JAHW075A Output Ripple Voltage April 2008 TIME μs/div) ...

Page 7

... Note: Tested with a 10 µF tantalum and a 1.0 µF ceramic capacitor across the load max Figure 11. Typical JAHW075A Transient Response 8-3203 (F) Note: Tested with a 10 µF tantalum and a 1.0 µF ceramic capacitor across the load. Figure 12.Typical JAHW100A Transient Response TIME, t (100 μs/div) ...

Page 8

... Vdc Input (Waveform Averaged to Eliminate Ripple Component.) TIME, t (50 μs/div) Note: Tested with a 10 µF tantalum and a 1.0 µF ceramic capacitor across the load. Figure 14. Typical JAHW075A Transient Response to Step Decrease in Load from 50 Room Temperature and O, max 48 Vdc Input (Waveform Averaged to Eliminate Ripple Component ...

Page 9

... Converters Vdc Input, 5 Vdc Output 100 W April 2008 Characteristic Curves (continued) TIME, t (20 ms/div) Figure 17.Typical JAHW100A Startup at applied TIME ms/div) Figure 18.Typical JAHW100A Remote Startup Lineage Power Test Configurations TO OSCILLOSCOPE L TEST 12 μH 220 μ ESR < 0.1 Ω °C, 100 kHz ...

Page 10

... As long as the fault persists, the module remains in this mode. The protection mechanism is such that the unit can continue in this condition for a sufficient interval of time until the fault is cleared. A latch-off option is also available April 2008 Lineage Power ...

Page 11

... I SENSE(–) V (–) I Figure 22. Remote On/Off Implementation Lineage Power Remote Sense Remote sense minimizes the effects of distribution losses by regulating the voltage at the remote-sense connections. The voltage between the remote-sense pins and the output terminals must not exceed the out- put voltage sense range given in the Feature Specifica- tions table, i ...

Page 12

... O V (+) I ON/OFF CASE V (–) I Figure 26. Circuit Configuration to Increase Output Voltage April 2008 V (+) O SENSE(+) TRIM R LOAD R adj-down SENSE(–) V (– CHANGE IN OUTPUT VOLTAGE (Δ%) V (+) O SENSE(+) R adj-up TRIM R LOAD SENSE(–) V (–) O Lineage Power 8-748 (F).b 40 8-3207 (F) 8-715 (F).b ...

Page 13

... The use of Figure 28 is shown in the following example. Example What is the minimum airflow necessary for a JAHW075A operating and a maximum ambient temperature of 55 °C? Solution Given ...

Page 14

... Figure 30. JAHW050A Power Dissipation vs 100 (°C) A 8-2236 ( Figure 31. JAHW075A Power Dissipation vs (° 1-0464 OUTPUT CURRENT, I (A) O Output Current at 25 °C ...

Page 15

... Lineage Power (continued) (continued) Figure 33. JAHW050A and JAHW075A Case-to 1-0465 These measured resistances are from heat transfer from the sides and bottom of the module as well as the top side with the attached heat sink; therefore, the case-to-ambient thermal resistances shown are gener- ally lower than the resistance of the heat sink by itself ...

Page 16

... Use Figure 33 to determine air velocity for the 1/2 inch heat sink. The minimum airflow necessary for the JAHW075A module is 0.5 m/s (100 ft./min.). 16 Custom Heat Sinks (continued) A more detailed model can be used to determine the (continued) required thermal resistance of a heat sink to provide necessary cooling. The total module resistance can be separated into a resistance from case-to-sink (θ ...

Page 17

... Top View Side View Bottom View 5.1 (0.20) 50.8 (2.00) 35.56 (1.400) * Side label includes Lineage name, product designation, safety agency markings, input/output voltage and current ratings, and bar code. † The case pin may be 1.3(0.05) longer than the other pins. Lineage Power 57.9 (2.28) 61.0 (2.40) 7.1 (0.28) STANDOFF, 12.7 (0.50) 4 PLACES V (–) ...

Page 18

... V Optional features can be ordered using the suffixes shown in Table 5. The suffixes follow the last letter of the device code and are placed in descending order. For example, the device codes for a JAHW075A module with the following options are shown below: Positive logic Negative logic Table 5 ...

Page 19

... Lineage Power reserves the right to make changes to the produc t(s) or information contained herein without notice. No liability is ass umed as a res ult of their use or applic ation. No rights under any patent acc ompany the sale of any oduct information. ...

Related keywords