OUTPUT SPECIFICATIONS 1
Operating Voltage (47-63 Hz) [Vrms]
Max. Load Current
Min. Load Current, [mArms]
Transient Overvoltage [Vpk]
Max. Surge Current, (16.6ms) [Apk]
Max. On-State Voltage Drop @ Rated Current [Vpk]
Thermal Resistance Junction to Case (R θJC ) [°C/W]
Maximum I 2 t for Fusing, (8.3 msec.) [A 2 sec]
Max. Off-State Leakage Current @ Rated Voltage [mArms]
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]
Max. Turn-On Time
Max. Turn-Off Time
Power Factor (Min.) with Max. Load
INPUT SPECIFICATIONS 1
Control Voltage Range
Max. Reverse Voltage
Max. Turn-On Voltage
Min. Turn-Off Voltage
Nominal Input Impedance
Typical Input Current
GENERAL NOTES
1
2
3
4
5
Series 1-110/125.
Rev. 012908
PAGE 1 OF 3
All parameters at 25°C unless otherwise specified.
Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
Heat sinking required, for derating curves see page 2.
Turn-on time for random turn-on versions is 0.02 msec (DC Control Models).
Input circuitry for 480V models incorporates active current limiter with 2mA typical input current..
M O D E L N U M B E R S
3
4
[Arms]
1500 Ohms (120/240V Models)
3.4mA @ 5 Vdc, 20mA @ 28Vdc
AC CONTROL
DC CONTROL
DC CONTROL
( D P R E F I X )
2
• Zero Voltage and Random
• Panel Mount
• Internal Snubber
• Integrated Overvoltage
3-32 Vdc
-32 Vdc
3.0 Vdc
1.0 Vdc
Turn-On Switching
Protection by Automatic
Self Turn-On (Suffix P)
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Inc., 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 606030 • FAX +44 (0)1202 606035 Crydom SSR Ltd., Arena Business Centre,
Holyrood Close, Poole, Dorset BH17 7FJ, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
5
5
A24110
D24110
24-280
9,340
1500
110
150
600
500
1.7
.25
0.5
10
2mA @ 120 Vrms, 4mA @ 240 Vrms
1/2 Cycle (DC Control), 10.0 msec (AC Control)
1/2 Cycle (DC Control), 40.0 msec (AC Control)
Series
90-280 Vrms (60Hz)
AC CONTROL
( A P R E F I X )
A24125
D24125
60K Ohms
24-280
12,700
1750
90 Vrms
10 Vrms
125
150
600
500
1.7
.22
0.5
10
© 2008 CRYDOM Inc., Specifications subject to change without notice.
- - -
Featuring state-of-the-art Surface
Mount Technology, these SPST-NO
relays deliver proven reliability in the
most demanding applications.
Output consists of an SCR AC switch
and is available in zero-cross, random
turn-on (phase controllable) and ver-
sions with either AC or DC input (coil)
control.
Manufactured in Crydom’s ISO 9001
Certified facility for optimum product
performance and reliability.
1-110/125A
120/240, 480 Vac - AC OUTPUT
HA48110
HD48110
48-530
9,340
1200
1500
110
150
500
1.7
.25
0.5
10
24V AC/DC CONTROL
18-36 Vrms/Vdc
( E S U F F I X )
4.0 Vrms/Vdc
18 Vrms/Vdc
3mA @ 24 V
9.0K Ohms
HA48125
HD48125
48-530
12,700
- - -
1200
1750
125
150
500
1.7
.22
0.5
10

Related parts for HD48110

HD48110 Summary of contents

Page 1

... input (coil) control. Manufactured in Crydom’s ISO 9001 Certified facility for optimum product performance and reliability. A24125 HA48110 HA48125 D24125 HD48110 HD48125 24-280 48-530 125 110 150 150 600 1200 1750 1500 1 ...

Page 2

AVAILABLE OPTIONS E 24V AC/DC Input Example: A24110E G Input Status LED. Agencies Approval Pending Example: HD48125G Note: Control Voltage Range 4.5-32Vdc for DC Control Models. P Internal Overvoltage Protection. Relay Will Self Trigger Between 450-600 Vpk (for 240Vac Models ...

Page 3

DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / PERIGO HAZARD OF RIESGO DE ELECTRIC DESCARGA SHOCK, ELECTRICA O EXPLOSION, EXPLOSION. OR ARC FLASH. • Desconectar • Disconnect all todos los power before suministros de installing or energia a este ...

Page 4

ANNEX – ENVIRONMENTAL INFORMATION: The environmental information disclosed in this annex including the EIP Pollution logo are in compliance with People’s Republic of China Electronic Industry Standard SJ/T11364 – 2006, Marking for Control of Pollution Caused by Electronic Information Products. ...