AD746 Analog Devices, AD746 Datasheet - Page 7

no-image

AD746

Manufacturer Part Number
AD746
Description
Dual Precision, 500 ns Settling, BiFET Op Amp
Manufacturer
Analog Devices
Datasheet

Specifications of AD746

Vcc-vee
9.6V to 36V
Isy Per Amplifier
4mA
Packages
DIP,SOIC
-3db Bandwidth
13MHz
Slew Rate
75V/µs
Vos
300µV
Ib
110pA
# Opamps Per Pkg
2
Input Noise (nv/rthz)
16nV/rtHz

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD7463ARQZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD7465JRZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD7466BRMZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD7466BRTZ-R2
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD7466BRTZREEL7
Manufacturer:
AD
Quantity:
4 922
Part Number:
AD7467ARQZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD7467BRMZ
Manufacturer:
Analog Devices Inc
Quantity:
135
Part Number:
AD746JN
Manufacturer:
AD
Quantity:
5 510
Part Number:
AD746JN
Manufacturer:
AD
Quantity:
1 000
Part Number:
AD746JR
Manufacturer:
AD
Quantity:
23
Part Number:
AD746JR
Manufacturer:
SOP-8
Quantity:
5 510
A HIGH SPEED 3 OR AMP INSTRUMENTATION
AMPLIFIER CIRCUIT
The instrumentation amplifier circuit shown in Figure 23 can
provide a range of gains from 2 up to 1000 and higher. The
circuit bandwidth is 2.5 MHz at a gain of 2 and 750 kHz at a
gain of 10; settling time for the entire circuit is less than 2 s to
within 0.01% for a 10 volt step, (G = 10).
Figure 23. A High Performance, 3 Op Amp, Instrumenta-
tion Amplifier Circuit
REV. B
Figure 24. Pulse Response of the 3
Op Amp Instrumentation Amplifier.
Gain = 10, Horizontal Scale:
0.5 s/Div, Vertical Scale: 5 V/Div.
–7–
Table I. Performance Summary for the 3 Op Amp
Gain
2
10
100
THD Performance Considerations
The AD746 was carefully optimized to offer excellent
performance in terms of total harmonic distortion (THD) in
signal processing applications. The THD level when operating
the AD746 in inverting gain applications will show a gradual
rise from the distortion floor of 20 dB/decade (see Figure 28).
In noninverting applications, care should be taken to balance
the source impedances at both the inverting and noninverting
inputs, to avoid distortion caused by the modulation of input
capacitance inherent in all BiFET op amps.
Instrumentation Amplifier Circuit
Figure 27. THD Measurement, Follower Circuit
Figure 26. THD Measurement, Inverter Circuit
20 k
4.04 k
404
R
Figure 25. Settling Time of the 3 Op
Amp Instrumentation Amplifier.
Gain = 10, Horizontal Scale: 0.5 s/Div,
Vertical Scale: 5 V/Div.
Error Signal Scale: 0.01%/Div.
G
Bandwidth
2.5 MHz
1 MHz
290 kHz
T
(0.01%)
AD746
1.0 s
2.0 s
5.0 s
SETTLE