ADP8863 Analog Devices, ADP8863 Datasheet - Page 38

no-image

ADP8863

Manufacturer Part Number
ADP8863
Description
Charge Pump, 7-Channel Fun Lighting LED Driver
Manufacturer
Analog Devices
Datasheet

Specifications of ADP8863

Vin Range
2.5 to 5.5V
Vout (v)
4.3 to 5.5
Synchronous
No
Package
20-Lead LFCSP,20-Lead WLCSP
Led Configuration
Parallel
Topology
Capacitive
I2c Support
Yes
Max Iout (ma)
60mA
Brightness Control
I2C
Peak Efficiency (%)
89%
Switching Frequency
1.32MHz
Over Volt Protection (v)
5V

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADP8863ACPZ-R7
Manufacturer:
ADI/亚德诺
Quantity:
20 000
ADP8863
Independent Sink Current Time (ISCT2)—Register 0x12
Table 46. ISCT2 Bit Map
Bit 7
Table 47. Bit Descriptions for the ISCT2 Register
Bit Name
SC4OFF
SC3OFF
SC2OFF
SC1OFF
1
2
To enable multiple independent sinks, set the appropriate SCx_EN bits. To create equivalent blinking and fading sequences, enable all independent sinks in one write
An independent sink remains on continuously when SCx_EN = 1 and SCxOFF = 00 (disabled).
cycle. This causes a preprogrammed sequence to start simultaneously.
SC4OFF
Bit No.
[7:6]
[5:4]
[3:2]
[1:0]
Bit 6
Description
SC4 off time. When the SC off time is disabled, the ISC remains on while enabled. When the SC off time is set to any
other value, the ISC turns off for the off time (per the following listed times) and then turns on according to the
SCON setting.
00 = off time disabled
01 = 0.6 sec
10 = 1.2 sec
11 = 1.8 sec
SC3 off time. When the SC off time is disabled, the ISC remains on while enabled. When the SC off time is set to any
other value, the ISC turns off for the off time (per the following listed times) and then turns on according to the
SCON setting.
00 = off time disabled
01 = 0.6 sec
10 = 1.2 sec
11 = 1.8 sec
SC2 off time. When the SC off time is disabled, the ISC remains on while enabled. When the SC off time is set to any
other value, the ISC turns off for the off time (per the following listed times) and then turns on according to the
SCON setting.
00 = off time disabled
01 = 0.6 sec
10 = 1.2 sec
11 = 1.8 sec
SC1 off time. When the SC off time is disabled, the ISC remains on while enabled. When the SC off time is set to any
other value, the ISC turns off for the off time (per the following listed times) and then turns on according to the
SCON setting.
00 = off time disabled
01 = 0.6 sec
10 = 1.2 sec
11 = 1.8 sec
Bit 5
1, 2
SC3OFF
Bit 4
Rev. A | Page 38 of 52
Bit 3
SC2OFF
Bit 2
Bit 1
SC1OFF
Bit 0

Related parts for ADP8863