MAXQ3180 Maxim, MAXQ3180 Datasheet - Page 77

no-image

MAXQ3180

Manufacturer Part Number
MAXQ3180
Description
The MAXQ3180 is a dedicated electricity measurement front-end that collects and calculates polyphase voltage, current, power, energy, and many other metering and power-quality parameters of a polyphase load
Manufacturer
Maxim
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MAXQ3180-RAN
Manufacturer:
MAXIM/美信
Quantity:
20 000
Part Number:
MAXQ3180-RAN+
Manufacturer:
SANKEN
Quantity:
23 000
Part Number:
MAXQ3180-RAN+T
Manufacturer:
MAXIM
Quantity:
10
Part Number:
MAXQ3180-RBN
Manufacturer:
MAXIM/美信
Quantity:
20 000
The MAXQ3180 can monitor the RMS value of one auxiliary channel in addition to its normal processing. The
Auxiliary Channel Configuration register selects which input the auxiliary channel processes and what processing is
applied to the auxiliary channel.
This register contains the system clock frequency in kHz units. Because the default frequency is 8MHz, this register
defaults to 0x1F40.
Bit:
Name:
Reset:
Bit:
Name:
Reset:
Bit:
Name:
Reset:
Bit:
Name:
Reset:
15:13, 5:3
12:8
BIT
2:0
7
6
AUX_MUX
ENHARM
ENAUX
NAME
ORDH
ENHARM
Low-Power, Multifunction, Polyphase AFE
______________________________________________________________________________________
15
15
0
7
0
7
Reserved.
Order of Harmonic (1–21). The output of harmonic voltage is read via virtual register 0x830 and current
at 0x840.
Enable Auxiliary Channel Harmonic Filter. When set, the auxiliary channel is processed through the
harmonic filter. The parameters for this filter can be set in the B0HARM and A1HARM registers.
Enable Auxiliary Channel. When set, enables auxiliary channel processing.
Auxiliary Channel Input Select. This three-bit field selects the input to be processed by the auxiliary
channel.
001 = I
010 = V
011 = I
100 = V
101 = I
110 = V
111 = I
ENAUX
N
A
B
C
A
B
C
14
14
0
6
0
6
13
13
0
5
0
5
System Clock Frequency High Byte
System Clock Frequency Low Byte
Auxiliary Channel Configuration (AUX_CFG) (0x010)
12
12
0
4
0
4
System Clock Frequency (SYS_KHZ) (0x012)
0x1F
0x40
FUNCTION
11
11
0
3
0
3
Neutral Current and Harmonics
ORDH
DSP System Configuration
10
10
0
2
0
2
AUX_MUX
9
0
1
0
9
1
8
0
0
0
8
0
77