Datasheet
IEC/EN/DIN EN 60747-5-2
**Approval Pending.
*Refer to the front of the optocoupler section of the current Catalog, under Product Safety Regulations section IEC/EN/DIN EN
60747-5-2, for a detailed description of Method a and Method b partial discharge test profiles.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits
in application.
Installation classification per DIN VDE
0110/1.89, Table 1
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
Input to Output Test Voltage, Method a*
Highest Allowable Overvoltage*
Safety-Limiting Values – Maximum Values
Insulation Resistance at T
for rated mains voltage
for rated mains voltage
for rated mains voltage
V
Test with t
Partial discharge < 5 pC
V
Test, t
Partial discharge < 5 pC
(Transient Overvoltage t
Allowed in the Event of a Failure, Also
See Figure 37, Thermal Derating Curve.
Case Temperature
Input Current
Output Power
IORM
IORM
m
x 1.875 = V
x 1.5 = V
= 60 sec,
m
Description
= 1 sec,
PR
, Type and Sample
PR
, 100% Production
S
, V
ini
Insulation Characteristics
IO
150 Vrms
300 Vrms
600 Vrms
= 10 sec)
= 500 V
P
Symbol
I
S, OUTPUT
S, INPUT
V
V
V
V
IORM
IOTM
T
R
PR
PR
S
S
HCPL-3150#060
55/100/21
1181
6000
I-IV
I-III
630
945
175
230
600
2
10
9
5
HCPL-315J**
55/100/21
1670
1336
6000
1200
891
175
400
I-IV
I-III
I-II
2
10
9
Vpeak
Vpeak
Vpeak
Vpeak
Unit
mW
mA
C