ITS 410E2 Infineon Technologies, ITS 410E2 Datasheet - Page 4

no-image

ITS 410E2

Manufacturer Part Number
ITS 410E2
Description
Manufacturer
Infineon Technologies
Datasheet

Specifications of ITS 410E2

Packages
PG-TO220-5
Channels
1.0
Ron @ Tj = 25°c
220.0 mOhm (max)
Recommended Operating Voltage Range
4.7 - 42.0 V
Il(sc)
12.0 A
Diagnostic
Digital
Protection Functions
7
8
9
10
Infineon Technologies AG
Parameter and Conditions
at T
Initial peak short circuit current limit (pin 3 to 5)
( max 450 s if V
Repetitive overload shutdown current limit
Short circuit shutdown delay after input pos. slope
Output clamp (inductive load switch off)
at V
Short circuit shutdown detection voltage
Thermal overload trip temperature
Thermal hysteresis
Reverse battery (pin 3 to 1)
Diagnostic Characteristics
Open load detection current
)
)
)
min value valid only, if input "low" time exceeds 60 s
V
) Requires 150
(pin 3 to 5)
V
(on-condition)
ON
j
Add I
Integrated protection functions are designed to prevent IC destruction under fault conditions described in the
data sheet. Fault conditions are considered as "outside" normal operating range. Protection functions are
not designed for continuous repetitive operation.
Short circuit current limit for max. duration of t
diode has to be limited by the connected load. Note that the power dissipation is higher compared to normal
operating conditions due to the voltage drop across the intrinsic drain-source diode. The temperature
protection is not active during reverse current operation! Input and Status currents have to be limited (see
max. ratings page 2 and circuit page 7).
ON
= 25 °C, V
OUT
> V
= 8 V, T
= V
ST
ON(SC)
, if I
bb
bb
ST
- V
,
j
= 12 V unless otherwise specified
= T
> 0, add I
ON(CL)
ON
resistor in GND connection. The reverse load current through the intrinsic drain-source
jt
> V
(see timing diagrams, page 12)
8 )
I
L
ON(SC)
IN
= 40 mA, T
, if V
I
L
= 1 A, T
10
IN
)
)
>5.5 V
T
T
j
j
j
=-40..+150°C:
=-40..+150°C: V
=-40..+150°C:
j
=-40 ..150°C:
T
j
T
=+150°C:
T
d(SC) max
j
j
=-40°C:
=25°C:
4
9
)
,
=450 s, prior to shutdown
I
I
t
V
T
-V
I
Symbol
L(SCp)
L(SCr)
d(SC)
L (OL)
jt
T
ON(CL)
ON(SC)
bb
jt
PROFET ® ITS 410 E2
150
min
61
--
--
--
--
--
--
--
9
4
2
Values
8.5
typ
12
68
10
--
--
--
--
--
--
--
5
2006-Mar-28
max
450
150
23
15
73
75
32
--
--
--
--
--
Unit
mA
°C
A
A
V
V
K
V
s

Related parts for ITS 410E2