STG940-Series Yamatake Corporation, STG940-Series Datasheet - Page 2

no-image

STG940-Series

Manufacturer Part Number
STG940-Series
Description
Pressure Transmitter
Manufacturer
Yamatake Corporation
Datasheet
No. SS2-STJ400-0100 (Rev.5)
APPLICATION
Petroleum / Petrochemical / Chemical
For measuring pressures and liquid levels in pipes and
tanks.
Electric power / City gas / Other utilities
For measurement applications that require high degrees of
stability and accuracy.
Pulp and paper
For lines that need transmitters resistant to chemical liq-
uids, corrosive fluids and the like.
Iron and steel / Nonferrous metal / Ceramics
For lines that require stable measurement under strictly
controlled (temperature, humidity, etc.) conditions.
Machinery / Shipbuilding
For lines that require stable measurement under strictly
controlled (temperature, humidity, etc.) conditions.
- 2 -
FUNCTIONAL SPECIFICATIONS
Type of protection
JIS C0920 watertight: NEMA3 and 4X
JIS F8001 class 2 watertight: IEC IP67
FM Explosionproof approval
FM Intrinsically safe approval
ATEX Flameproof approval
ATEX Intrinsic safety
NEPSI Flameproof approval
NEPSI Intrinsically safe approval
CSA Explosion-proof Approval
EMC Conformity
PED Conformity (97/23/EC)
Explosionproof for Class I (Gas, steam), Division 1,
Group A, B, C, D
Dust-ignition for Class II (Inflammable dust), Divi-
sion 1, Group E, F, G
Suitable for Class III (inflammable fiber), Division 1
Nonincendive for Class I, Division 2, Group A, B, C, D
Intrinsically safe for Class I, II, III, Division 1, Group
A, B, C, D, E, F, G
Certificate number: INERIS99ATEX0010 X
Certificate number: KEMA03ATEX1225 X
Electrical data: Ui = 30V
SPECIAL CONDITIONS FOR SAFE USE (X)
Because the enclosure of the Smart Pressure Transmit-
ter is made of aluminium, if it is mounted in an area
where the use of category 1 G apparatus is required, it
must be installed such, that, even in the event of rare
incidents, ignition sources due to impact and friction
sparks are excluded.
Ex d II T6 (with NEPSI Dust Ignition DIP DT T13)
Ex ia IIC T5 at -20 < Tamb < +60°C
Ex ia IIC T6 at -20 < Tamb < +40°C
CSA Explosion-proof for Class I, (Division 1),
Groups A, B, C and D
CSA Flameproof for Class I, Zone 1, Ex d IIC T6 at
ambient temp. = -20°C to +60°C
CSA Dust-ignitionproof for Class II and III, (Divi-
sion 1), Groups E, F and G
89/336/EEC, 92/31/EEC, 93/68/EEC Electromagnetic
Compatibility (EMC) Directive
Comply with Module H (with “H1” option), or SEP
(Sound Engineering Practice) for models of which
maximum working pressure is 200 bar or lower.
Lowest temperature for Module H
Bolt/nut material SNB7:
II 2 GD EExd IIC T6 at -20 < Tamb < +60°C
II 1 G EEx ia IIC T4 at -20 < Tamb < +60°C
Ii = 100 mA
Pi = 1W
Ci = 3 nF
Li = 0.5 mH
SUS630: -6°C
Yamatake Corporation
-10°C

Related parts for STG940-Series