ACST-118 Abracon Corporation, ACST-118 Datasheet

no-image

ACST-118

Manufacturer Part Number
ACST-118
Description
Current Sense Inductor
Manufacturer
Abracon Corporation
Datasheet
Current Sense Inductor & Transformer
ISO 9001 / QS 9000
ISO 9001 / QS 9000
ABRACON IS
ABRACON IS
SCHEMETIC
CERTIFIED
CERTIFIED
·FREQUENCY RANGE FROM 200 TO 500 KHz
·1250 Vrms ISOLATION
·20Amp PEAK SENSE CURRENT
FEATURES:
ELECTRICAL SPECIFICATIONS:
NOTE
OUTLINE DRAWING
ABRACON P/N:
Part number Part number
ACST-118-
1. Inductance Test: 200KHz/ 200 mV
2. Terminating resistance for 0.15Volt/Amp
3. Hipot: 2000V
ACST- 118
Inductor
1A
2A
3A
INDUCTOR
N I
D
Transformer
U
ACST-118-
C
ACST-118-SERIES
T
RMS
O
1B
2B
3B
R
, Primary to secondary
OCL
(Min)
4000
150
600
μH
1
(mV)
160
V
30
60
S
(±2%)
Turns
Sec
10
20
50
30332 Esperanza, Rancho Santa Margarita, California 92688
tel 949-546-8000
Visit www.abracon.com for Terms & Conditions of Sale
• SMPS
• Current Sensing
APPLICATIONS:
Sec DCR Pri DCR
(Max)
0.055
0.097
0.240
Ω
T
TRANSFORMER
R
Pb
A
N
S
|
F
fax 949-546-8001
O
(Max)
0.006
0.006
0.006
R
RoHS
Compliant
M
Ω
E
R
Dimension: Inch/mm
RT
1.5
3.0
7.5
Ω
13.97 x 8.26 x 14.73 mm
| www.abracon.com
2
Revised: 02.22.08

Related parts for ACST-118

Related keywords