MPF048 Martek Power, MPF048 Datasheet

no-image

MPF048

Manufacturer Part Number
MPF048
Description
Dc/dc Converter
Manufacturer
Martek Power
Datasheet
>
>
>
>
Input transients voltage
Reverse input voltage protection
Inrush current limitation
Product reference
Nominal output voltage
Output voltage ripple p-p
(WB 0 to 30 MHz)
Nominal output current
Crossed regulation (load + line)
Nominal output power
Efficiency
Thermal protection
Switching frequency
Output current limitation
Overvoltage protection
Permanent short circuit protection
Product reference
Operating temperature range
Derating
Storage temperature range
Temperature coefficient
Relative humidity at 40°C
Cooling
Insulation resistance
Dielectric strength
MTBF (UTE C 80-810)
Coating
Protection index
Environmental Details
101 VDC during 1 s
Yes, by reverse diode
+ external micro circuit breaker
Yes, by NTC
MPF 048 1K01
From 5 to 24 VDC
< 100 m V
2 A
< 5%
48 W
70% under 5 VDC
80% under 24 VDC
No
> 50 kHz, fixed
< 1,2 I nominal
No
Yes
MPF 048 1K01
-25°C to +70°C
No
-40°C to +85°C
< 2.10
95%
Natural convection
>100MΩ, 500 VDC (Input / Output)
2 100 VDC (Input / Ground)
> 1 000 000 h at 40°C
PCB coated with varnish
IP 20
-4
/°C
>>>
4