TR20BNW-TA Fuji Electric holdings CO.,Ltd, TR20BNW-TA Datasheet - Page 6

no-image

TR20BNW-TA

Manufacturer Part Number
TR20BNW-TA
Description
Thermal Overload Relays
Manufacturer
Fuji Electric holdings CO.,Ltd
Datasheet
On-contactor
mounting
Separate mounting
Contactor to be combined
Rated operational
current (A)
Ampere setting range (A)
Specify the setting range code
when ordering.
On-contactor
mounting
Separate mounting
Contactor to be combined
Rated operational
current (A)
Ampere setting range (A)
Specify the setting range code
when ordering.
Notes: *
Notes: Conforming to Class AC-15, DC-13, IEC, JIS, and JEM.
Type
TR-0N, 5-1N
TR-0N/3, 5-1N/3
TK-0N, 5-1N
TR-0NQ, 5-1NQ
TR-N2 to N8
TR-N2/3 to N8/3
TK-N2 to N8
TR-N2Q to N5Q
TR-N10 to N14
TR-N10/3 to N14/3
TK-N10 to N14
Thermal Overload Relays
TR series
Quick operating type
01/102
Selection guide/Quick operating type
Ratings of auxiliary contact
( )* NO contact of auto reset type.
*
( ) Basic ordering code
1
2
Thermal overload relay with phase-loss protection is available with *
N2Q to N5Q.
Type numbers are TK-0NQ, TK-5-1NQ, TK-N2Q to N5Q. The setting ranges of these TK- Q type relays are as same as those of the above setting ranges.
Separate mounting only.
Rated
thermal
current
(A)
3
5
5
3-element
3-element
3-element
3-element
Code
Code
Rated
voltage
(V)
100-120 2.5 (0.3)*
200-240 2 (0.3)*
380-440 1 (0.3)*
500-600 0.6 (0.3)*
100-120 2.5 (0.5)*
200-240 2 (0.5)*
380-440 1 (0.5)*
500-600 0.6 (0.5)*
100-120 2.5 (0.3)*
200-240 2 (0.3)*
380-440 1 (0.3)*
500-600 0.6 (0.3)*
24
24
24
200–240V
380–440V
200–240V
380–440V
W
M
G
M
N
R
U
B
B
P
S
V
X
E
E
T
F
J
L
Rated AC
operational
current
(A)
3 (0.3)*
3 (0.5)*
3 (0.3)*
TR-N3Q (TR65BSW)
TR-N3Q (TR65BSW)
SC-N2S
52
48
18–26
24–36
28–40
34–50
TR-0NQ (TR13SW)
SC-03
11
1.4 – 2.2
1.7 – 2.6
2.2 – 3.4
2.8 – 4.2
9
4 – 6
5 – 8
6 – 9
7 – 11 *
1
Rated DC
operational
current
(A)
1.1 (0.3)*
0.28
0.14
1.1(0.3)*
0.28
0.14
1.1(0.3)*
0.28
0.14
SC-N3
65
65
18–26
24–36
28–40
34–50
45–65
53–80*
65–95*
SC-0
SC-05
13
12
1.4 – 2.2
1.7 – 2.6
2.2 – 3.4
2.8 – 4.2
4 – 6
5 – 8
6 – 9
7 – 11 *
9 – 13 *
2
2
1
1
1
marked setting ranges of TR-0NQ, TR-5-1NQ and all setting ranges of TR-
TR-N5Q (TR80SW)
SC-N4
80
80
18–26
24–36
28–40
34–50
45–65
53–80
TR-5-1NQ (TR20SW)
SC-4-0
18
16
1.4 – 2.2
1.7 – 2.6
2.2 – 3.4
2.8 – 4.2
12 – 18 *
Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog
4 – 6
5 – 8
6 – 9
7 – 11 *
9 – 13 *
1
1
1
SC-N5
105
105
18–26
24–36
28–40
34–50
45–65
53–80
65–95
SC-4-1
SC-5-1
22
22
1.4 – 2.2
1.7 – 2.6
2.2 – 3.4
2.8 – 4.2
12 – 18 *
4 – 6
5 – 8
6 – 9
7 – 11 *
9 – 13 *
Information subject to change without notice
1
1
1
TR-N2Q (TR35BSW)
SC-N1
27
30
12 – 18
18 – 26
SC-N2
39
37
12 – 18
18 – 26
24 – 36