RDS Power-One, RDS Datasheet - Page 2

no-image

RDS

Manufacturer Part Number
RDS
Description
Rds Dc-dc Series Rds Dc-dc Series
Manufacturer
Power-One
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
RDS035L03
Manufacturer:
STM
Quantity:
550
Part Number:
RDS035L03
Manufacturer:
ROHM/罗姆
Quantity:
20 000
Part Number:
RDS035L03TB
Manufacturer:
HUALIAN
Quantity:
7 280
Part Number:
RDS035L03TB
Manufacturer:
ROHM/罗姆
Quantity:
20 000
Part Number:
RDS04ZG-S1
Quantity:
48
Part Number:
RDS4-3,3
Manufacturer:
KASCHKE
Quantity:
986
Part Number:
RDS616
Quantity:
1
Part Number:
RDS626
Manufacturer:
FUJISOKU
Quantity:
700
Part Number:
RDSP020
Manufacturer:
CONEXANT
Quantity:
1 000
Part Number:
RDSP020
Manufacturer:
CONEXANT
Quantity:
20 000
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings may cause performance degradation, adversely affect long
term reliability and cause permanent damage to the converter. Specifications apply over specified input voltage,
output load and temperature range, unless otherwise noted.
Environmental and Mechanical Specifications
Specifications apply over specified input voltage, output load and temperature range, unless otherwise noted.
Isolation Specifications
Specifications apply over specified input voltage, output load and temperature range, unless otherwise noted.
Input Specifications
Specifications apply over specified input voltage, output load and temperature range, unless otherwise noted.
NOV 11, 2005 revised to JUN 29, 2006
Input voltage (Vin)
Transient Input Voltage (Vint)
Operating CaseTemp. (Tc)
Storage Temperature (Ts)
ON/OFF Control Voltage (Vrc)
Shock
Sinusoidal Vibration
Weight
Water Washing
MTBF
Insulation Safety Rating
Isolation Voltage (Vps)
Isolation Resistance (Rps)
Isolation Capacitance (Cps)
Input Voltage (Vin)
Input Current when Shutdown
Turn-On Input Voltage 36-75 Vin
Turn-Off Input Voltage 36-75 Vin
Turn-On Time
Input Reflected Ripple Current
Input Capacitance
Parameter
Parameter
Parameter
Parameter
Per Bellcore TR-NWT-000332
To Output Regulation Band
Conditions/Description
Conditions/Description
(100% load @25°C, GB)
Vin.Nom, Remote Control
Conditions/Description
RDS04ZG, RDS05ZE
Ramping Down, Io.Max
After Remote Control
Vin = 36 – 75 VDC
Ramping Up, Io.Max
Standard process
Conditions/Description
Vin.Max, Io.Max
IEC68-2-27
Referenced to -Vin
IEC68-2-6
RDS06ZB
Transient, 100 ms
Continuous
Rise Time
activated
At 100% load
Continuous
Page 2 of 12
20W SMT Converter
RDS DC-DC Series Data Sheet
Min
Min
10
Min
36
32
30
4,700
2,200
1,452
Nom
Min
-1.0
Nom
-40
-55
Basic
36
Nom
600
Yes
48
34
32
30
3
5
1.8V to 5V Output
Max
100
100
120
1,500
5.5
0.6/17
75
Max
Max
Max
100
1.4
75
10
36
34
50
10
www.power-one.com
MOhm
mADC
mAp-p
Units
Units
Units
VDC
VDC
VDC
Units
VDC
VDC
VDC
VDC
kHrs
oz/g
N/A
N/A
°C
°C
ms
ms
ms
μF
pF
g
g

Related parts for RDS