S1D13700 Epson Electronics America, Inc., S1D13700 Datasheet - Page 27

no-image

S1D13700

Manufacturer Part Number
S1D13700
Description
LCD Controller ICs
Manufacturer
Epson Electronics America, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
S1D13700F01A100
Manufacturer:
MTK
Quantity:
5 000
Part Number:
S1D13700F01A100
Manufacturer:
Epson Electronics America Inc-Semiconductor Div
Quantity:
10 000
Part Number:
S1D13700F01A100
Manufacturer:
EPSON/爱普生
Quantity:
20 000
Part Number:
S1D13700F02A100
Manufacturer:
M/A-COM
Quantity:
400
Part Number:
S1D13700F02A100
Manufacturer:
Epson Electronics America Inc-Semiconductor Div
Quantity:
10 000
Part Number:
S1D13700F02A100
Manufacturer:
SEIKO
Quantity:
20 000
8.2. System Control Commands
8.2.1. SYSTEM SET
Initializes the device, sets the window sizes, and selects
the LCD interface format. Since this command sets the
basic operating parameters of the S1D13305 series, an
8.2.1.1. C
This control byte performs the following:
1. Resets the internal timing generator
2. Disables the display
3. Cancels sleep mode
Parameters following P1 are not needed if only can-
celing sleep mode.
8.2.1.2. M0
Selects the internal or external character generator ROM.
The internal character generator ROM contains 160, 5
7 pixel characters, as shown in figure 70. These charac-
ters are fixed at fabrication by the metallization mask.
The external character generator ROM, on the other
hand, can contain up to 256 user-defined characters.
M0 = 0: Internal CG ROM
M0 = 1: External CG ROM
S1D13305 Series
Technical Manual
P1
P2
P3
P4
P5
P6
P7
P8
C
MSB
WF
D7
0
0
0
D6
1
0
0
0
D5
0
IV
0
0
Figure 1. SYSTEM SET instruction
D4
0
0
0
1
TC/R
APH
APL
C/R
L/F
W/S
D3
0
0
EPSON
D2
M2
0
D1
FY
M1
0
incorrect SYSTEM SET command may cause other
commands to operate incorrectly.
Note that if the CG ROM address space overlaps the
display memory address space, that portion of the display
memory cannot be written to.
8.2.1.3. M1
Selects the memory configuration for user-definable char-
acters. The CG RAM codes select one of the 64 codes
shown in figure 46.
M1 = 0: No D6 correction.
The CG RAM1 and CG RAM2 address spaces are not
contiguous, the CG RAM1 address space is treated as
character generator RAM, and the CG RAM2 address
space is treated as character generator ROM.
M1 = 1: D6 correction.
The CG RAM1 and CG RAM2 address spaces are
contiguout and are both treated as character generator
RAM.
FX
D0
M0
0
LSB
A0
1
0
0
0
0
0
0
0
0
WR
0
0
0
0
0
0
0
0
0
RD
1
1
1
1
1
1
1
1
1
INSTRUCTION SET
21