TM450 Tumbler Technologies + TRUMPower, TM450 Datasheet

no-image

TM450

Manufacturer Part Number
TM450
Description
Trumpower Medical Power Supplies - Open Frame Ac/dc Power Supply Selection Guide; Medically Approved To Ul 60601-1, Tuv En60601-1
Manufacturer
Tumbler Technologies + TRUMPower
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TM4505P
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
TRUMPower
D E S C R IP T IO N
The TM450 series comprising single and multiple
output models for 450-480 watts of continuous
output power is specially designed for medical
applications. They operate at 90 to 264VAC input
voltage without the need of a selector strap. The
units are constructed on a printed circuit board
with a U-bracket for mechanical support and heat
sinking. A cover-and-fan assembly can be added
during manufacturing.
F E AT U R E S
‧ E N 6 1 0 0 0 - 3 - 2 c l a s s A a n d D c o m p l i a n t
‧ P o w e r F a c t o r 0 . 9 8 t y p i c a l
‧ O v e r v o l ta g e p r o t e c t i o n
‧ S h o r t - c i r c u i t p r o t e c t i o n
‧ T h e r m a l p r o t e c t i o n
‧ P o w e r F a i l D e t e c t ( P F D )
‧ 1 0 0 % b u r n - i n a t f u l l r a t e d l o a d
‧ R e m o t e s e n s e o n o u t p u t # 1 a n d o u t p u t # 2
‧ R e m o t e i n h i b i t – T T L h i g h d i s a b l e s o u t p u t
‧ C o m p l i a n t w i t h R o H S r e q u i r e m e n ts
INPUT SPECIFICATIONS
I n p u t v o l ta g e :
I n p u t f r e q u e n c y :
I n p u t c u r r e n t :
E a r t h l e a k a g e c u r r e n t: 1 0 0 µ A m a x . @ 11 5 VA C , 6 0 H z
Output voltage/current:
Total output power:
Ripple and Noise:
Overvoltage protection:
Overcurrent protection:
Temperature coefficient: All outputs ±0.04%/ºC maximum
Transient response:
PFD signal:
Remote inhibit:
O U T P U T S P E C I F I C AT I O N S
Phone: 408-988-6616 ● Fax: 408-988-6622 ● email: sales@trumpower.com ● Website: www.TRUMPower.com
9 0 t o 2 6 4 VA C
4 7 t o 6 3 H z
7 . 1 A ( r m s ) f o r 11 5 VA C
3 . 5 A ( r m s ) f o r 2 3 0 VA C
1 6 5 µ A m a x . @ 2 3 0 VA C , 5 0 H z
See rating chart
See rating chart
2% peak to peak maximum
Provided on output #1 only; set
at 115 – 140% of its nominal
output voltage
All outputs protected to short
circuit conditions
Maximum excursion of 4% or
better on all models, recovering
to 1% of final value within 500µs
after a 25% step load change
TTL logic high for normal
Operation and TTL logic low
upon loss of input power. This
signal appears at least 1ms prior
to master output dropping
5% below its nominal value.
This signal also provides a
minimum delay of 100ms
after master output is within
regulation.
Requires an external TTL high
level signal to inhibit outputs for
standard models.
3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA
Tumbler Technologies + TRUMPower
450 WATT MEDICAL POWER SUPPLIES
E N V I R O N M E N TA L S P E C I F I C AT I O N S
O p e r a t i n g t e m p e r a t u r e : 0 º C t o + 7 0 º C
S t o r a g e t e m p e r a t u r e :
R e l a t i v e h u m i d i t y :
D e r a t i n g :
S a f e t y Sta n d a r d A p p r o va l s :
GENERAL SPECIFICATIONS
Switching
frequency:
Power factor:
Efficiency:
Hold-up time:
Line regulation:
Inrush current:
Withstand voltage: 4000VAC from input to output
MTBF:
EMC Performance (EN60601-1-2)
EN55011:
EN61000-3-2:
EN61000-3-3:
EN61000-4-2:
EN61000-4-3:
EN61000-4-4:
EN61000-4-5:
EN61000-4-6:
EN61000-4-8:
TM450 SERIES
UL 60601-1
CSA C22.2 No. 601.1
TÜV EN60601-1
60KHz ±10KHz
0.98 typical
80% minimum on all models
12 msec minimum at 110VAC
±0.2% maximum at full load
40 amps @ 115VAC or 80 amps
@ 230VAC, at 25ºC cold start
1500VAC from input to ground
500VAC from output to ground
300,000 hours minimum at full load
at 25ºC ambient, calculated per
MIL-HDBK- 217F
Class B conducted, Class A
radiated
Harmonic distortion, Class A and D
Line flicker
ESD, ±8KV air and ±6KV contact
Radiated immunity, 3V/m
Fast transient/burst, ±2KV
Surge, ±1KV diff, ±2KV com.
Conducted immunity, 3Vrms
Magnetic field immunity, 3A/m
Voltage dips, 30% reduction for
500ms, 60% reduction for 100ms
and >95% reduction for 10ms
- 4 0 º C t o + 8 5 º C
5 % t o 9 5 % n o n - c o n d e n s i n g
D e r a t e f r o m 1 0 0 % a t + 5 0 º C
l i n e a r l y t o 5 0 % a t + 7 0 º C
RoHS
( LV D )

Related parts for TM450

TM450 Summary of contents

Page 1

... TRUMPower The TM450 series comprising single and multiple output models for 450-480 watts of continuous output power is specially designed for medical applications. They operate 264VAC input voltage without the need of a selector strap. The units are constructed on a printed circuit board with a U-bracket for mechanical support and heat sinking ...

Page 2

... TM450-T37 48V 0.5A 6A NOTES: 1. Add suffix “C” for enclosed format with fan control function, e.g. TM450-S24C. 2. All outputs are floating. It can be connected externally for positive or negative output. 3. Output #1 can be adjusted within ±5% of their nominal voltage. 4. Output #3 can be adjusted within ±15% of their nominal voltage. ...

Page 3

... INHIBIT N.C. N.C. 0V (FAN) -Ve P1 (AC +V1 -V1 NEUTRAL GROUND INHIBIT +S (V2) -S (V2) 0V (FAN) -Ve Tumbler Technologies + TRUMPower TM450 SERIES SIGNAL GROUND +S (V) -S (V) (-V) 10 FAN SIGNAL GROUND +S (V1) -S (V1) (- +V2 -V2 N ...

Related keywords