CMA3000-D0X VTI Hamlin, CMA3000-D0X Datasheet - Page 6

no-image

CMA3000-D0X

Manufacturer Part Number
CMA3000-D0X
Description
Cma3000-d0x Series 3-axis Accelerometer
Manufacturer
VTI Hamlin
Datasheet
1.2.4
1.2.5
1.2.5.1
1.2.5.2
1.2.5.3
1.2.5.4
1.2.6 Interrupt
VTI Technologies Oy
www.vti.fi
Supported features
Operation modes
Power Down
Measurement
Motion Detection
Free-Fall Detection
Supported features are listed in Table 1 below.
Table 1. CMA3000-D0X devices’ summary.
Features
Supply voltage
I/O voltage
Measuring range (selectable)
Resolution (2g /8g range)
Sensitivity (2g /8g range)
Motion detection
Free fall detection
Interface
Clock
In Power Down (PD) mode device's volatile register keep their contents and the current
consumption is minimized. Power down mode is the default mode after start up.
In Measurement mode (Meas) the sensor offers acceleration information via the digital SPI/I
interface. Interrupt can be activated via INT-pin, when each xyz-acceleration sample is ready to be
read.
Measurement range and sample rate are user selectable according to Table 2. Measurement mode
can be activated by detected motion.
Motion Detection (MD) mode is intended to be used to save system level power consumption. In
this mode, CMA3000-D0X activates the interrupt via the INT-pin when motion is detected. Motion
sensitivity level can be configured via the SPI or I
detected can be user defined. Once the interrupt has happened, the detected direction can be read
out from the corresponding status register.
Low sample rate (10 Hz) band-pass filtered acceleration information is available in MD mode. The
device can be configured to switch automatically into the measurement mode with highest
sampling rate after motion detection.
Free-Fall Detection (FFD) is intended to be used to save system resources. This feature activates
the interrupt via the INT-pin when free-fall is detected. Acceleration information is available when
the FFD is enabled.
The CMA3000 has a dedicated output pin (INT) to be used as the interrupt for the master
controller. Interrupt conditions can be activated and deactivated via the SPI or I
interrupt has happened, the interrupt source can be read out from the corresponding status
register.
Doc.Nr. 8281000.12
CMA3000-D01
1.7 V – 3.6 V
1.7 V – 3.6 V
±2 g, ±8 g
17 mg / 67 mg
56 counts/g / 14 counts/g
User enabled
User enabled
SPI max 500 kHz, I
Internal
2
C bus. Moreover, duration of the motion to be
2
C fast mode 400 kHz
CMA3000-D0X Series
2
C bus. Once the
Rev. 0.12
6/ 35