NCP1380 ON Semiconductor, NCP1380 Datasheet - Page 17

no-image

NCP1380

Manufacturer Part Number
NCP1380
Description
Quasi-Resonant Current Mode Controller
Manufacturer
ON Semiconductor
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
NCP1380A
Manufacturer:
ON/安森美
Quantity:
20 000
Part Number:
NCP1380ADR2G
Manufacturer:
ON Semiconductor
Quantity:
327
Part Number:
NCP1380B
Manufacturer:
ON/安森美
Quantity:
20 000
Part Number:
NCP1380BDR2G
Manufacturer:
ON
Quantity:
20
Part Number:
NCP1380BDR2G
Manufacturer:
ON Semiconductor
Quantity:
9 750
Part Number:
NCP1380BDR2G
Manufacturer:
ON/安森美
Quantity:
20 000
Part Number:
NCP1380BDR2G
0
Company:
Part Number:
NCP1380BDR2G
Quantity:
5 000
Part Number:
NCP1380C
Manufacturer:
ON/安森美
Quantity:
20 000
Part Number:
NCP1380CDR2G
Manufacturer:
ON Semiconductor
Quantity:
2 000
Company:
Part Number:
NCP1380CDR2G
Quantity:
2 500
Company:
Part Number:
NCP1380CDR2G
Quantity:
70
Part Number:
NCP1380D
Manufacturer:
ON/安森美
Quantity:
20 000
Part Number:
NCP1380DDR2G
Manufacturer:
ON
Quantity:
3 080
Part Number:
NCP1380DDR2G
0
Company:
Part Number:
NCP1380DDR2G
Quantity:
320
Company:
Part Number:
NCP1380DDR2G
Quantity:
200
www.DataSheet4U.com
Time Out
comparator can be unable to detect the valleys. To avoid
such situation, NCP1380 integrates a Time Out function that
acts as a substitute clock for the decimal counter inside the
logic bloc. The controller thus continues its normal
operation. To avoid having a too big step in frequency, the
time out duration is set to 5.5 ms. Figures 34 and 35 detail the
time out operation.
the soft−start.
auxiliary winding is low. Because of the voltage drop
In case of extremely damped free oscillations, the ZCD
The NCP1380 also features an extended time out during
Indeed, at startup, the output voltage reflected on the
Figure 32. Zoom 4: 4
Figure 31. Zoom 3: 3
http://onsemi.com
th
Valley to VCO Mode Transition
rd
17
to 4
introduced by the Over Power Compensation diode
(Figure 40), the voltage on the ZCD pin is very low and the
ZCD comparator might be unable to detect the valleys. In
this condition, setting the DRV Latch with the 5.5 ms
time−out can lead to a continuous conduction mode
operation (CCM) at the beginning of the soft−start. This
CCM operation only last a few cycles until the voltage on
ZCD pin becomes high enough to be detected by the ZCD
comparator. To avoid this, the time−out duration is extended
to 40 ms during the soft−start in order to ensure that the
transformer is fully demagnetized before the MOSFET is
turned−on.
th
Valley Transition

Related parts for NCP1380