160
The data in bold type pertain to the standard versions of the relays.
www.relpol.com.pl
Contact data
Number and type of contacts
Contact material
Rated / max. switching voltage
Min. switching voltage
Rated load
Min. switching current
Rated current
Max. breaking capacity
Min. breaking capacity
Contact resistance
Max. operating frequency
• at rated load
• no load
Coil data
Rated voltage
Must release voltage
Operating range of supply voltage
Rated power consumption
Power consumption at pickup voltage
Max. continuous dissipation
Insulation
Insulation rated voltage
Rated surge voltage
Overvoltage category
Insulation pollution degree
Insulation resistance
Dielectric strength
• between coil and contacts
• contact clearance
• pole - pole
Contact - coil distance
• clearance
• creepage
General data
Operating / release time (typical values)
Electrical life
• resistive AC1
• AC7a
Mechanical life (cycles)
Dimensions (L x W x H)
Weight
Ambient temperature
Cover protection category
Environmental protection
Shock resistance
Vibration resistance
Solder bath temperature
Soldering time
RS35
according to PN-EN 60664-1
RS35, RS50
industrial relays for solar systems
Export Sales Department Phone +48 68 47 90 832 • Marketing Department Phone +48 68 47 90 900
RS50
• storage
• operating
AC1
DC1
AC1
DC1
AC1
DC
DC
AC
• Relays for power control in solar systems generating energy
• Max. switching current: 35 A (version RS35); 50 A (version RS50)
• 5000 V / 10 mm reinforced insulation
• Contact gap > 1,75 mm • Holding power 0,1 W
• For PCB • DC coils • Reinforced insulation, acc. PN-EN 60730-1
• Recognitions, certifications, directives: RoHS,
(VDE 0631, part 1); PN-EN 60335-1 (VDE 0700, part 1)
2 NO
AgSnO
250 V / 440 V
10 V
RS35:
RS35:
10 mA
RS35:
RS35:
RS35:
1 W
≤ 50 mΩ
360 cycles/hour
3 600 cycles/hour
5...110 V
DC:
see Table 1
0,48 W
0,3 W
1,9 W
250 V AC
4 000 V
III
3
1000 MΩ
5 000 V AC
2 500 V AC
2 500 V AC
≥ 10 mm
≥ 10 mm
30 ms / 5 ms
5 x 10
3 x 10
10
40 x 25 x 49,2 mm
105 g
-40...+105
-40...+85
IP 40
RTI
10 g
1,5 mm DA
max. 270
max. 5 s
6
≥ 0,05 U
35 A / 250 V AC
35 A / 24 V DC
35 A
8 750 VA
90 W
4
4
2
35 A, 250 V AC, 20 °C
35 A, 250 V AC, 20 °C
o
o
C
C
1,2 / 50 µs
o
at 20 °C
PN-EN 60529
PN-EN 116000-3
C
(constant amplitude)
0,3 A / 300 V
n
type of insulation: reinforced
type of clearance: full-disconnection
type of insulation: basic
10...55 Hz
RS50:
RS50:
RS50:
RS50:
RS50:
5 x 10
3 x 10
48 A / 250 V AC
48 A / 24 V DC
50 A
12 500 VA
90 W
4
4
50 A, 250 V AC, 20 °C
50 A, 250 V AC, 20 °C
0,3 A / 300 V