bcp-5-3.3 C&D Technologies., bcp-5-3.3 Datasheet

no-image

bcp-5-3.3

Manufacturer Part Number
bcp-5-3.3
Description
Dual Output, Mixed Voltage, Isolated 5v & 3.3 V, Half-brick 75 W Dc/dc Converters
Manufacturer
C&D Technologies.
Datasheet
FEATURES
n
n
n
n
n
n
n
n
n
n
n
n
n
Independent 5V and 3.3V outputs
Each output fully regulated
No minimum load requirements
Up to 15 Amps per output
75 Watts total output power
Standard "half-brick" package
UL1950, EN60950-1 and VDE safety
approvals (BASIC insulation)
Fully isolated, 1500Vdc guaranteed
18-36V or 36-75V input ranges
CE mark available (75V-input models)
Input under and overvoltage shutdown
Continuous short-circuit protection
Thermal shutdown
www.murata-ps.com/rohs
For full details go to
 
SIMPLIFIED SCHEMATIC
CONTROL
ON/OFF
+INPUT
–INPUT
(3)
(4)
(1)
PRODUCT OVERVIEW
As your new, mixed-logic (5V and 3.3V) design
evolves and your current requirements change,
your new DC/DC converter will not. Murata Power
Solutions' BCP-5/15-3.3/15-D24 (18-36V input)
and BCP-5/15-3.3/15-D48 (36-75V input) are fully
isolated DC/DC converters providing both 5V and
3.3V outputs. Housed in standard "half-brick"
packages (2.3" x 2.4" x 0.525"), the BCP’s can
support any combination of 5V and 3.3V loading
up to a combined total of 15 Amps. Both outputs
are fully isolated (1500Vdc) and independently line
(±0.2%) and load (±0.5% and ±0.6%) regulated.
undervoltage and overvoltage shutdown, input
reverse-polarity protection, output overvoltage
Both BCP models feature input pi filters, input
www.murata-ps.com
COMPARATORS
UV & OV
CONTROLLER
PWM
Dual Output, Mixed Voltage, Isolated 5V & 3.3 V,
CONTROL
SWITCH
CONTROLLER
ISOLATION
MAG AMP
Technical enquiries email: sales@murata-ps.com, tel:
OPTO
"Half-Brick" 75 W DC/DC Converters
protection, current limiting, and thermal shutdown.
Each has an on/off control function, and the two
output voltages can be trimmed independently.
(50mVp-p), high efficiency (87%) and are fully
specified for –40 to +100°C operation. Utilization of
metal baseplate technology with threaded inserts
permits easy heat-sink attachment and/or pcb
mounting. These devices meet IEC950, UL1950,
EN60950-1 and VDE safety standards, includ-
ing BASIC insulation requirements. CB reports
are available on request. "D48" models are CE
marked (meet the requirements of LVD). Selected
models are available with RoHS-6 hazardous
substance compliance.
BCP Model DC/DC’s deliver low noise
REFERENCE &
REFERENCE &
ERROR AMP
ERROR AMP
MDC_BCP_75W.B02 Page 1 of 14
BCP Models
Typical topology is shown
+5V OUTPUT
+3.3V OUTPUT
3.3V TRIM
5V TRIM
+1 508 339 3000
5V RETURN (6)
3.3V RETURN
(5)
(8)
(7)
(10)
(9)

Related parts for bcp-5-3.3

bcp-5-3.3 Summary of contents

Page 1

... BCP-5/15-3.3/15-D48 (36-75V input) are fully isolated DC/DC converters providing both 5V and 3.3V outputs. Housed in standard "half-brick" packages (2.3" x 2.4" x 0.525"), the BCP’s can support any combination of 5V and 3.3V loading combined total of 15 Amps. Both outputs are fully isolated (1500Vdc) and independently line (± ...

Page 2

... Pin length: 0.145 in. (3.68mm) ±0.010, quantity order -Y RoHS-5 Hazardous substance compliance, with lead -C RoHS-6 Hazardous substance compliance, no lead Note: Some model number combinations may not be available. Contact Murata Power Solutions. Technical enquiries email: sales@murata-ps.com, tel: MDC_BCP_75W.B02 Page Package  (Case/ Typ. Pinout) 87.2% C19, P29 88% ...

Page 3

... THICK THERMAL PAD INCLUDED Dimensions are in inches (mm shown for ref. only). Third Angle Projection Tolerances (unless otherwise specified): .XX ± 0.02 (0.5) .XXX ± 0.010 (0.25) Angles ± 2˚ Components are shown for reference only. Technical enquiries email: sales@murata-ps.com, tel: MDC_BCP_75W.B02 Page 0.20 (5.1) 1.900 2.30 (48.3) (58.4) 0.47 (11.9) ...

Page 4

... Input Current must be limited. 1 minute duration. Fusing recommended. 6 Amps 4 Amps 3.8 Volts, latching 6.2 Volts, latching Current limited. Devices can withstand an indefinite output short circuit. –40 to +120°C +300°C Technical enquiries email: sales@murata-ps.com, tel: MDC_BCP_75W.B02 Page 508 339 3000 ...

Page 5

... & 3.3V Outputs/Returns The BCP Series outputs (pins 7 & 10) and returns (pins 6 & 9) are isolated from the +V and –V inputs (pins 4 & 1) via a transformer and opto-coupled IN IN transistors. The +5V Return (pin 6) and +3.3V Return (pin 9) are connected internal to the DC/DC converter ...

Page 6

... This new heat sink (HS-CPLP2) is designed with radiant fins that extend 0.51" beyond either side of the 2.4" dimension of the BCP package. The convenience of this design is that the finned extensions protrude only 0.31" below the top surface of the DC/DC converter, allowing components with a profile height less than 0.215" ...

Page 7

... Output Trimming Both the 5V and 3.3V outputs of the BCP Series can be independently trimmed via a trimpot (Figure 3A single fixed resistor as shown (Figures 3B & 3C). The trimpot can be used to determine the value of a single fixed resistor. A single fixed resistor can increase or decrease the output voltage depending on its connection. Fixed resistors should be metal-film types with absolute TCR’ ...

Page 8

... Output Full-Load to Half-Load Transient Response (V = 48V, 3.3V@ 0A, external 10µF || 1µF output capacitors.) IN 15A 7.5A 100µsec/div 5V Output Half-Load to Full-Load Transient Response (V = 48V, 3.3V@ 0A, external 10µF || 1µF output capacitors.) IN 15A 7.5A 100µsec/div Technical enquiries email: sales@murata-ps.com, tel: MDC_BCP_75W.B02 Page 508 339 3000 ...

Page 9

... Output Half-Load to Full-Load Transient Response (V = 48V, 5V@ 0A, external 10µF || 1µF output capacitors.) IN 15A 7.5A 100µsec/div Input Ripple Current (V = 48V 15A, 3.3V@ 0A, external 22µF low-ESR input capacitor.) IN 1µsec/div Technical enquiries email: sales@murata-ps.com, tel: MDC_BCP_75W.B02 Page 508 339 3000 ...

Page 10

... IN 1µsec/div Start-Up from Remote On/Off Control (V = 48V, 5V@ 7.5A, 3.3V @ 7.5A, external 10µF || 1µF output capacitors.) IN 4msec/div Start-Up from 48V, 5V@ 7.5A, 3.3V @ 7.5A, external 10µF || 1µF output capacitors.) IN 4msec/div Technical enquiries email: sales@murata-ps.com, tel: MDC_BCP_75W.B02 Page 508 339 3000 ...

Page 11

... Ambient Temperature (°C) Natural Convection Cooling 150 Linear Feet Per Minute 300 Linear Feet Per Minute Ambient Temperature (°C) Technical enquiries email: sales@murata-ps.com, tel: MDC_BCP_75W.B02 Page 100 90 95 100 80 90 100 +1 508 339 3000 ...

Page 12

... 60V 48V 36V IN 3.75 5.625 7.5 9.375 11.25 +5V Output Current (Amps 60V 48V 36V 75V IN 3.75 5.625 7.5 9.375 11.25 +3.3V Output Current (Amps) Technical enquiries email: sales@murata-ps.com, tel: MDC_BCP_75W.B02 Page 100 13.125 15 13.125 15 +1 508 339 3000 ...

Page 13

... W DC/DC Converters D48 Model +3. and +5V @15A +3.3V @ 3.75A and +5V @11.25A +3.3V @ 7.5A and +5V @7.5A +3.3V @ 15A and +5V @0A 40.4 44.7 49 53.3 57.7 62 66.3 Input Voltage (Volts) PARD 3.3V Output PARD 5V Output Ripple 3.3V Output Ripple 5V Output 40.71 46.43 52.14 57.86 63.57 69.29 Input Voltage (Volts) Technical enquiries email: sales@murata-ps.com, tel: MDC_BCP_75W.B02 Page 70 508 339 3000 ...

Page 14

... Options and Adaptations Optional Functions The BCP 75W DC/DC Dual Half-Bricks offer various electrical and mechani- cal options. Per the Ordering Guide on page 2, the trailing input voltage range (D24 or D48) in each part number pertains to the base part number. Part- number suffixes are added after the "input range," indicating the selection of standard options. The resulting part number is a " ...