○ Cautions on use
(2) Recommended Operating conditions
(3) Reverse connection of power supply connector
(4) Power supply line
(5) GND voltage
(6) Short circuit between terminals and erroneous mounting
(7) Operation in strong electromagnetic field
(8) Inspection with set PCB
(9) Input terminals
(10) Ground wiring pattern
(11) External capacitor
(12) Rush current
(1) Absolute Maximum Ratings
An excess in the absolute maximum ratings, such as supply voltage, temperature range of operating conditions, etc., can break
down devices, thus making impossible to identify breaking mode such as a short circuit or an open circuit. If any special mode
exceeding the absolute maximum ratings is assumed, consideration should be given to take physical safety measures including
the use of fuses, etc.
These conditions represent a range within which characteristics can be provided approximately as expected. The electrical
characteristics are guaranteed under the conditions of each parameter.
The reverse connection of power supply connector can break down ICs. Take protective measures against the breakdown due to
the reverse connection, such as mounting an external diode between the power supply and the IC’s power supply terminal.
Design PCB pattern to provide low impedance for the wiring between the power supply and the GND lines.
In this regard, for the digital block power supply and the analog block power supply, even though these power supplies has the
same level of potential, separate the power supply pattern for the digital block from that for the analog block, thus suppressing the
diffraction of digital noises to the analog block power supply resulting from impedance common to the wiring patterns. For the
GND line, give consideration to design the patterns in a similar manner.
Furthermore, for all power supply terminals to ICs, mount a capacitor between the power supply and the GND terminal. At the
same time, in order to use an electrolytic capacitor, thoroughly check to be sure the characteristics of the capacitor to be used
present no problem including the occurrence of capacity dropout at a low temperature, thus determining the constant.
Make setting of the potential of the GND terminal so that it will be maintained at the minimum in any operating state. Furthermore,
check to be sure no terminals are at a potential lower than the GND voltage including an actual electric transient.
In order to mount ICs on a set PCB, pay thorough attention to the direction and offset of the ICs. Erroneous mounting can break
down the ICs. Furthermore, if a short circuit occurs due to foreign matters entering between terminals or between the terminal and
the power supply or the GND terminal, the ICs can break down.
Be noted that using ICs in the strong electromagnetic field can malfunction them.
On the inspection with the set PCB, if a capacitor is connected to a low-impedance IC terminal, the IC can suffer stress. Therefore,
be sure to discharge from the set PCB by each process. Furthermore, in order to mount or dismount the set PCB to/from the jig
for the inspection process, be sure to turn OFF the power supply and then mount the set PCB to the jig. After the completion of
the inspection, be sure to turn OFF the power supply and then dismount it from the jig. In addition, for protection against static
electricity, establish a ground for the assembly process and pay thorough attention to the transportation and the storage of the set
PCB.
In terms of the construction of IC, parasitic elements are inevitably formed in relation to potential. The operation of the parasitic
element can cause interference with circuit operation, thus resulting in a malfunction and then breakdown of the input terminal.
Therefore, pay thorough attention not to handle the input terminals, such as to apply to the input terminals a voltage lower than
the GND respectively, so that any parasitic element will operate. Furthermore, do not apply a voltage to the input terminals when
no power supply voltage is applied to the IC. In addition, even if the power supply voltage is applied, apply to the input terminals a
voltage lower than the power supply voltage or within the guaranteed value of electrical characteristics.
If small-signal GND and large-current GND are provided, It will be recommended to separate the large-current GND pattern from
the small-signal GND pattern and establish a single ground at the reference point of the set PCB so that resistance to the wiring
pattern and voltage fluctuations due to a large current will cause no fluctuations in voltages of the small-signal GND. Pay attention
not to cause fluctuations in the GND wiring pattern of external parts as well.
In order to use a ceramic capacitor as the external capacitor, determine the constant with consideration given to a degradation in
the nominal capacitance due to DC bias and changes in the capacitance due to temperature, etc.
For ICs with more than one power supply, it is possible that rush current may flow instantaneously due to the internal powering
sequence and delays. Therefore, give special consideration to power coupling capacitance, power wiring, width of GND wiring,
and routing of wiring.