z02215 ZiLOG Semiconductor, z02215 Datasheet

no-image

z02215

Manufacturer Part Number
z02215
Description
Single Chip Modem With Integrated Controller, Data Pump, And Analog Front End
Manufacturer
ZiLOG Semiconductor
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
z0221524AECR50A5
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
z0221524AECR50A5TR
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
z0221524AEGR50A5
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
z0221524ASC
Manufacturer:
NXP
Quantity:
20
Part Number:
z0221524ASC
Manufacturer:
ZILOG
Quantity:
20 000
Part Number:
z0221524ASCR4508
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
z0221524ASCR4508TR
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
z0221524VSC
Manufacturer:
ZILOG
Quantity:
20 000
Part Number:
z0221524VSCR50A5
Manufacturer:
SMSC
Quantity:
2 249
Part Number:
z0221524VSCR50A5
Manufacturer:
ZILOG
Quantity:
20 000
Z02215
Single Chip Modem with
Integrated Controller, Data
Pump, and Analog Front End
Product Specification
PS001907-0904
ZiLOG Worldwide Headquarters • 532 Race Street • San Jose, CA 95126
Telephone: 408.558.8500 • Fax: 408.558.8300 •
www.ZiLOG.com

Related parts for z02215

z02215 Summary of contents

Page 1

... Z02215 Single Chip Modem with Integrated Controller, Data Pump, and Analog Front End Product Specification PS001907-0904 ZiLOG Worldwide Headquarters • 532 Race Street • San Jose, CA 95126 Telephone: 408.558.8500 • Fax: 408.558.8300 • www.ZiLOG.com ...

Page 2

This publication is subject to replacement by a later edition. To determine whether a later edition exists request copies of publications, contact: ZiLOG Worldwide Headquarters 532 Race Street San Jose, CA 95126 Telephone: 408.558.8500 Fax: 408.558.8300 www.ZiLOG.com ZiLOG ...

Page 3

... STATIC REVERSE Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Escape Sequences . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 TIES Escape Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 Carrier Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 Blacklisting Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 Configurations and Data Rates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 Data Encoding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 Transmitted Data Spectrum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 Active Hybrid Circuit and Relay Driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 Operating Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 Dynamic Power Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 Clock Oscillator Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 PS001907-0904 Z02215 iii Table of Contents ...

Page 4

... Single Chip Modem with Integrated Controller, Data Pump, and AFE Country Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 Typical Performance Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 Absolute Maximum Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 Standard Test Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 Available Operating Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . 59 Voltage Supply Range Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Capacitance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 Analog Inputs: Type Analog Outputs: Type Package Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 Z02215 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 PS001907-0904 Z02215 iv Table of Contents ...

Page 5

... Single Chip Modem with Integrated Controller, Data Pump, and AFE List of Figures Figure 1. Z02215 Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Figure 2. Z02215 44-Lead PLCC Pin Identification (for Prototype Only Figure 3. Z02215 44-Lead LQFP Pin Identification . . . . . . . . . . . . . . . . . . . . . 5 Figure 4. Modem State Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Figure 5. Oscillator Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Figure 6. Typical Performance Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 Figure 7 ...

Page 6

... Table 10. Spectral Shaping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 Table 11. Suggested Crystal Specifications (C1=C2=20pF*, C0=2pF Table 12. Absolute Maximum Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 Table 13. Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Table 14. Environmental Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Table 15. DC Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Table 16. Microprocessor Interface Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 Table 17. Serial Interface Timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 Table 18. Parallel Interface Timing Table 19. Analog Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 PS001907-0904 Z02215 vi List of Tables ...

Page 7

... Programmable transmit attenuation and selectable receive threshold • Fully-programmable call progress detectors for precise call program monitoring, including signal quality detectors, tone detectors, tone generators, and transmit signal levels that aid in rapid country qualifications • On-chip peripheral, a full-duplex voice band AFE with 12-bit resolution PS001907-0904 Z02215 1 Features ...

Page 8

... PLCC, 44-Pin LQFP footprint • Single +5 VDC power supply • Minimal external logic • 0°C to +70°C standard temperature range and –40°C to +85°C extended temper- ature range International Telecommunications Union (ITU, formerly known Note: as CCITT) PS001907-0904 Z02215 2 Features ...

Page 9

... Input. This configuration eliminates the need for external filtering components. The analog front end of the Z02215 includes an active hybrid circuit that improves modem performance and reduces system-level costs by reducing the requirement for external components ...

Page 10

... Single Chip Modem with Integrated Controller, Data Pump, and AFE Power connections follow these conventional descriptions: Connection Power Ground RESET Serial/ Parallel Interface Controller EEPROM Interface (Optional) RAM/ ROM Internal Figure 1. Z02215 Block Diagram PS001907-0904 Circuit Device GND V SS Oscillator Data Pump Analog Z02202 ...

Page 11

... Pin Descriptions AV DD TxO+ TxO– A GND V REF A GND CF1 CF2 RxI– RxI Figure 2. Z02215 44-Lead PLCC Pin Identification (for Prototype Only TxO+ TxO– A GND V REF A GND CF1 CF2 RxI– RxI Figure 3. Z02215 44-Lead LQFP Pin Identification ...

Page 12

... CF1 to complete the internal feedback integration filter for improved analog A/D performance. Analog Connect an 82pF capacitor between CF2 and Input CF1 to complete the internal feedback integration filter for improved analog A/D performance. Analog These are the analog inputs from the DAA. Input Z02215 6 Pin Descriptions ...

Page 13

... SHTREL works in conjunction with pulse dial make/break. It offers extra-low resistance across the tip and ring. When all relays are closed, SHRTEL provides 100 Ohms (Low) instead of 600 Ohms. Output This signal is used to turn on the off-hook relay in the DAA. Z02215 7 Pin Descriptions ...

Page 14

... Hz. Input Active Low, Parallel mode only. When this pin goes Low, data transfer between the Z02215 Parallel Interface and the Host are enabled. Data transfers are 8 bits wide. Output Active Low, Serial mode only. The serial receive data from the DSP is presented on this pin ...

Page 15

... Direction Description Input/ Serial mode only. This line can be configured Output as an input or output on a bit-by-bit basis. Parallel mode only. Address bit 0 for the Input Parallel interface. High level selects the PICR register; Low selects the PIDT register. Z02215 9 Pin Descriptions ...

Page 16

... Serial or Parallel Mode Select Parallel Host Interface With the Parallel Host Interface, a host controller can put the Z02215 on its pro- cessor bus and access peripheral.The Parallel Interface consists of two host registers: • Register 0–Parallel Interface Data Register (PIDR) • ...

Page 17

... Single Chip Modem with Integrated Controller, Data Pump, and AFE PIDR is the data register for transmitting and receiving data, including the AT com- mands. In RECEIVE DATA mode (when HRD, HCS, HA0, S/P are Low), Z02215 reads the data on the Host Parallel Data bus (HD0–HD7) for the external host to read the contents. ...

Page 18

... Handshaking takes place at the beginning of each connection between two modems. The originator and answerer of a connection perform different actions while handshaking. The modem does not accept AT commands or pass data from the terminal while hand- shaking. PS001907-0904 DIALING HANDSHAKE IDLE ON-LINE Z02215 12 Operating Modes ...

Page 19

... The modem does not execute any of the commands in a command AT line that is too long. To echo command line characters, use the PS001907-0904 are ignored. Command lines contain, at most, 40 characters AT command. E1 Z02215 13 command. Data O and A T >. Characters CR AT Command Set ...

Page 20

... AT command line. OK Command lines may contain several commands one after another. The Answer ( ), Dial ( ), and Go ON-LINE ( A D mands in the command line to be ignored. PS001907-0904 and characters are entered commands usually cause the following com- O Z02215 >, BS character. The modem Ctrl-X AT Command Set 14 ...

Page 21

... CR command line. PS001907-0904 (and the special characters such as < < > and ATH CR ATH0 : . T 13 Z02215 > and < >) are ignored not provided. 0 < > both hang up the telephone CR and . The modem uses A T ...

Page 22

... S-register S37 also contributes to the selection of the modulation standard. This register sets the telephone line data rate, and the split rate data mode (Bell 202/ Bell 202T or V.23). Both modems must be configured identically to prevent communication failures caused by incompatible telephone line modulation standards. PS001907-0904 Z02215 16 AT Command Set ...

Page 23

... Bell 202 is utilized. The answering modem transmits data at 150 bps and receives data at 1200 bps. When S-register S37 is set to any value other than then a setting of B2 operates set. This option is the same as B0. Z02215 17 AT Command Set ...

Page 24

... DCD reflects the state of the carrier signal from the other modem using S-registers S9 and S10. This command is the default value in North America. This command reflects the state of the carrier signal from the other modem using S-registers S9 and S10. Z02215 18 AT Command Set ...

Page 25

... See “Dial Modifiers” on page 34 for more information. PS001907-0904 This command does not display Caller ID information. This option is the default value. This command returns the information as formatted data. This command returns the information as unformatted data. This command returns the current setting of the #CID=command. Z02215 19 AT Command Set ...

Page 26

... If in the ON-LINE state, the modem goes into the COMMAND state, and issues an OK result code. The modem hangs up the telephone line and issues an OK result code. Auto-Answer is disabled as long as DTR remains OFF. The modem resets. Z02215 20 & ...

Page 27

... North America. Retrain is not initiated automatically. Retraining is initiated if the data pump indicates retraining is required. This value is the default value. S1=0 S2=43 S3=13 S7=30 S8=2 S9=6 S17=10 S25=5 S28 &C0 %E1 \N1 \Q3 \R0 Z02215 S4=10 S5=8 S10=14 S11=95 S29=25 S37=0 &D0 &G0 &P0 &K3 &Q0 AT Command Set 21 ...

Page 28

... Detect DTMF digits with out using a human speech filter. DTMF digits as short can be detected. Detect DTMF digits while using a filter that reduces the effect of human speech on the detection of DTMF digits, improving the accuracy of detection. DTMF digits as short can be detected. Z02215 22 AT Command Set ...

Page 29

... No guard tone. This value is the default value in North America. 550 Hz guard tone (V.22, V.22bis and Bell 212A only) 1800 Hz guard tone (V.22, V.22bis and Bell 212A only) Off-hook. Off-hook without answering a telephone call. This option may be disabled in countries prohibiting its use. Z02215 23 AT Command Set ...

Page 30

... DTMF tone “B” DTMF tone “C” DTMF tone “D” V.21 channel 1 mark V.21 channel 2 marks V.23 1200bps marks V.23 75bps marks V.21 channel 1 spaces V.21 channel 2 spaces V.23 1200bps spaces V.23 75bps spaces V.22 originate mode V.22 answer mode V.22bis originate mode V.22bis answer mode V.25 calling tone Z02215 24 AT Command Set ...

Page 31

... Software Versions. The modem reports its software versions and release date. Modem Identification. The modem reports a configurable identification message to the terminal. This option disables flow control. This option enables RTS/CTS flow control. Same as \Q3. This option enables XON/XOFF Flow control. Same as \Q1. Z02215 25 AT Command Set ...

Page 32

... In V.22bis, V.22 and Bell 212A data modes, data from the terminal is converted to SYNCHRONOUS format using ITU V.14 to adjust for small (up to 2.5%) timing discrepancies in the data rate without the use of flow control. This value is the default value. Z02215 26 AT Command Set ...

Page 33

... For this option, result codes are displayed. This value is the default value for North America. Result codes are not displayed. Z02215 27 AT Command Set ...

Page 34

... S0 has been set to answer the telephone line (S0 > 0) and the number of signals received is greater than the value of S0 (see S-Register S1) then the modem answers. Otherwise, the modem originates. The modem hangs up when DTR goes from ON to OFF for longer in time than the value of S-register S25. Z02215 28 AT Command Set ...

Page 35

... The modem treats XON and XOFF characters sent from the terminal to the modem as data characters. Download a table of parameters as ASCII hexadecimal characters. Use this format when the host controller uses a parity bit on data transmitted to the modem. Z02215 29 AT Command Set ...

Page 36

... The modem uses the copies of these parameters kept in the optional EEPROM, or the ROM. PS001907-0904 Download a table of parameters as binary 8-bit data. Use this format when the host controller sends 8-bit data to the modem (that is, when no parity bit is used on data sent to the modem). Z02215 30 AT Command Set ...

Page 37

... Minitel operation with line reversals, it automatically detects the rate switch and changes its own transmit and receive data rates. See “Minitel Line Reversal” on page 44 for details. Note: R may be followed the O command in the command line to return ON- LINE immediately. PS001907-0904 Z02215 31 AT Command Set ...

Page 38

... Sn command. The =x command writes the value x to the last S-register named in the Sn command. The range of valid values for x depends upon the S-register being written. The value 0 is assumed if no value is provided for x. Selects the tone method of dialing. Z02215 32 AT Command Set ...

Page 39

... Both a busy signal and a dial tone are detected. When a telephone line connection is made, the result code indicates the telephone line data rate. This value is the default value in North America. Z02215 33 AT Command Set ...

Page 40

... NO DIALTONE result code. , Delay processing of next character. A comma (,) causes the modem to pause for the length of time in S-register S8 before processing the next character in a dial string. PS001907-0904 before dialing extension number 1234. #7 Z02215 34 Dial Modifiers ...

Page 41

... When ON-LINE, the modem recognizes the Escape Sequence (+++) and modem commands only at 1200 bps. 300 bps. Refer to the Communication Standard Options (B) command for a description. Reserved 1200 bps. Refer to the Communication Standard Options (B) command for a description. 2400 bps Z02215 35 Setting the Highest Line Rate ...

Page 42

... BLACKLISTED The modem does not allow any number to be dialed until the modem is reset. 21 DELAYED The modem does not allow any number to be dialed now, until a specified time period elapses. PS001907-0904 Z02215 36 Result Codes ...

Page 43

... Sets the line feed character. S-register S4 is the value of the character for line feed. Sets the backspace character. S-register S5 is the value of the character for backspace. This character moves the cursor left on a command line, deleting the previous character. Z02215 37 Modem S-Registers ...

Page 44

... Delay to wait when a comma dial modifier is processed. S-register S8 is the duration of the delay when the comma (,) command or dial modifier is processed. Time carrier must be present before being recognized. S- register S9 is the number of tenths of a second a carrier signal must be present before the modem recognizes it Z02215 38 Modem S-Registers ...

Page 45

... Escape prompt delay time. Register S12 is the prompt delay time for escape sequences from the ON-LINE state to the COMMAND state. Sets transmit level. The actual transmit power used is adjustable by the country configuration to accommodate differences in transformers and other components in the telephone line interface. Z02215 39 Modem S-Registers ...

Page 46

... In case of conflict between the B option and S37, S37 takes precedence. Configure both modems identically to prevent communication failures caused by incompatible telephone line modulation standards. See “Setting the Highest Line Rate” on page 21 for different Communication Standards. Z02215 40 Modem S-Registers ...

Page 47

... Bit 5: USE_AP_CMD, set to allow the pulse dial make/break ration to be set (AT&P). Bit 6: DISABLE_P_AFTER_T, set to disable pulse dialing after tone dialing (no ATDT12P12). Bit 7: LINE_SENSE_ENABLE, set to enable line current sensing before taking the modem off-hook (ATA, ATD, auto- answer) Z02215 41 Modem S-Registers ...

Page 48

... Bit 4: BLIST_ENABLED, set to enable blacklisting. See BL_MINDELAY_S and related parameters. Bit 5: FRANCE_CALL_DELAY, set to force France call originate delay after ring. Bit 6: VOICE_ANSWER, set to enable detection of voice answer. Bit 7: DTMF_S11, set to use S11 instead of DTMFINTERDIGITMS for the delay between dialed DTMF digits. Z02215 42 Modem S-Registers ...

Page 49

... Bit 5: MCSLEEP_DISABLE, set =1 to prevent the Z02215 from being put to sleep when idle. Placing the Z02215 in sleep mode reduces power consumption by approximately 8 mA. Disabling sleep mode may increase the modem's reliability, some modem designs experience occasional problems waking after sleep ...

Page 50

... Entering REVERSE mode Entering NORMAL mode escape command or by making an active/inactive DTR transi- +++ has been previously executed). The user then sends the command followed by an command). As the modem supports O TIES), R Z02215 ATRO the following command may be command, and returns ON-LINE. Minitel Line Reversal 44 ...

Page 51

... Carrier Detect CD / code to the Host. The CD then goes active. 1200 / code to the Host. The CONNECT 1200 75 NO CARRIER Z02215 hard- RTS changes from active (logic signal ( ) goes inactive, the CD then goes active CD code to the Host. ...

Page 52

... The modem uses S-register S9 to deter- mine how long a carrier must be present before it is detected. The modem uses S- register S10 to determine how long a carrier may not be detected before the tele- phone line is disconnected. PS001907-0904 command). The terminal has complete control of this signal, and it Z02215 46 Carrier Detection ...

Page 53

... Blacklisting period in minutes for each series of dial attempts Technical Specifications Configurations and Data Rates The Z02215 can be configured to any of the V.22bis operation modes. Table 9 provides the selectable options, the supported data rate, and the baud rate, and frequency to be modulated. Data Encoding The data encoding for the Z02215 meets ITU– ...

Page 54

... Note: The carrier and the spectral shaping are selected automatically according to the Configuration. Active Hybrid Circuit and Relay Driver An active hybrid circuit is added to the Analog Front End (AFE) of the Z02215 to improve the received signal quality level by 20dB and to improve the modem per- formance ...

Page 55

... Operating Notes Dynamic Power Management The Z02215 incorporates a low-power SLEEP mode. In this mode, the clock is stopped. The modem controller software automatically puts the modem's data pump into a power-saving SLEEP mode when it is not in use. The modem controller software also puts the modem controller to SLEEP when possible ...

Page 56

... Refer to the Application Note titled Crystal Oscillator for Embedded 100K Modems at: http://www.zilog.com/pdfs/modem/ appnote_crystal.pdf EXTAL R = 100 * Device ground pin =C 1 ° C Z02215 – The C values are dependent =20pF*, C =2pF Value ° ° +70 C ° ...

Page 57

... Single Chip Modem with Integrated Controller, Data Pump, and AFE Country Configuration The Z02215 contains modem controller code that is targeted to operate over a North America-style telephone network with the DAA configuration illustrated in the schematics at the end of this product specification. The customer may choose to configure the modem for use on other telephone networks ...

Page 58

... Tubes (GDTs). The shunt relay reduces the DAA impedance during pulse dialing. This relay is required for certain country approvals. The CID relay pro- vides a signal path (through C4) to receive Caller ID signals without taking the line off-hook. PS001907-0904 Z02215 52 Country Configuration ...

Page 59

... V.22bis low band V.22bis high band V.23, 1200 bps V.23, 75 bps Z02215 Data Pump Version 0x50, External Hybrid, V.22 1200 bps Line Type: Flat Receive Level (line): -30 dBm 10^7 bits per sample 1 dB S/N steps AGC & AEQ frozen 1.E-02 1.E-03 V.22 low band V.22 high band 1 ...

Page 60

... Receive Level (line): -30 dBm 10^6 bits per sample 1 dB S/N steps AGC & AEQ frozen 1.E-02 1.E-03 1.E-04 1.E- Z02215 Line Type: Flat Receive Level (line): -30 dBm 1 dB S/N steps AGC & AEQ frozen Bell 202, 1200 bps Bell 202, 134.5 bps - ...

Page 61

... Single Chip Modem with Integrated Controller, Data Pump, and AFE AVDD 17 AVDD 7 VDD 33 VDD 2 VDD 27 Figure 8. Typical Modem Employing the Z02215 (Serial Mode) PS001907-0904 AGND 12 AGND 10 GND 3 GND 23 GND 28 GND 34 Z02215 55 Country Configuration ...

Page 62

... Single Chip Modem with Integrated Controller, Data Pump, and AFE AVDD 17 AVDD 7 VDD 33 VDD 2 VDD 22 Figure 9. Typical Modem Employing the Z02215 (Parallel Mode) PS001907-0904 AGND 12 AGND 10 GND 3 GND 23 GND 28 GND 34 Z02215 56 Country Configuration ...

Page 63

... Single Chip Modem with Integrated Controller, Data Pump, and AFE Figure 10. Data Access Arrangement (DAA) PS001907-0904 Z02215 57 Country Configuration ...

Page 64

... Total power dissipation must not exceed 820W for the package. Power dissipation is calculated as follows: Total Power Dissipation PS001907-0904 sum of [(V + sum of (V Z02215 Min Max Units Notes 0 +70 C – –55 +150 C –0.6 +7 ...

Page 65

... Single Chip Modem with Integrated Controller, Data Pump, and AFE Standard Test Conditions The DC Parameters are be tested according to the DC Characteristics detailed in Table 15. The Z02215 tester has active loads which are used to test the loading for I and I OH OR. Available Operating Temperature Range ° ...

Page 66

... C to +70 ° –40 ° –55 –0.3V to +7V 352mW +230 Test Conditions Minimum 2.0 -0.3 GND < V < V – –.20 mA 2.4 OH Z02215 ° Current Maximum @ 0 C 90mA 25mA ° C ° +85 C ° +150 C ° C Typical Maximum Units – – ...

Page 67

... REF –20 –100 – – V –1.163 V REF V –40 REF –40 – – 400 Voltage 4 Operating – Operating – SLEEP Mode – SLEEP Mode – Z02215 Typical Maximum Units – 0.4 V µA – 1 0.3 0.6 – – V µA – ...

Page 68

... Table 16. Microprocessor Interface Timing Reset Timing Reset Pulse Width TCLK TXD RCLK 1 RXD Figure 11. Serial Port Timing Diagram PS001907-0904 = GND = 0V 1.0 MHz, unmeasured pins to GND. Minimum Maximum Parameter Minimum Typical 1.0 – Z02215 62 Maximum Units µs – Capacitance ...

Page 69

... CS, and A0 setup before WR Data setup before WR Data hold from WR WR pulse width PS001907-0904 Parameter Minimum 1 – 2 100 3 100 Parameter Minimum Typical Z02215 Typical Maximum Units 12 – ns – – ns – – ns Maximum Units Capacitance ...

Page 70

... TDi S 30 – Symbol Minimum Typical C – – +2.5 DCOFF V –2.362 – PKI V –1.181 – PKIP Z02215 64 Typical Maximum Units 1200 – W 26.5 32.5 kHz ° C) and voltage coefficient of Maximum Units Ω – – –72 dBm – ...

Page 71

... Symbol Minimum Typical Z – 0.80 OUT C – 10 OUT V –2.375 – PKO ZI 400 600 Z02215 65 Maximum Units – dB – dB –72 dBm dBm dBm dBm dBm Maximum Units Ω – – pF +2.375 V – – Analog Outputs: Type A0 ...

Page 72

... Single Chip Modem with Integrated Controller, Data Pump, and AFE Package Information Figure 13. 44-Lead PLCC Package Diagram (for Prototype Only) Figure 14. 44-Lead LQFP Package Diagram PS001907-0904 Z02215 66 Package Information ...

Page 73

... V = Plastic Leaded Chip Carrier A = Very small Quad Flat Pack S = 0×C to +70×C (Standard –40×C to +85×C (Extended Plastic Standard R50A5 = ROM code number 50A5 (DSP ROM code Version 0x51, Controller ROM code version 2.0) Z02215 67 Standard Temp Standard Temp Extended Temp Ordering Information ...

Page 74

... Single Chip Modem with Integrated Controller, Data Pump, and AFE Example A5 Z 02215 PS001907-0904 is a Z02215 with ROM code R50A5, 24.576 MHz, LQFP, 0×C to +70×C, Plastic Standard Flow ROM Code Number ROM Code Designator Environmental Flow Temperature ...

Related keywords