mlx90614 Melexis Company, mlx90614 Datasheet - Page 17

no-image

mlx90614

Manufacturer Part Number
mlx90614
Description
Single And Dual Zone Infra Red Thermometer In To-39
Manufacturer
Melexis Company
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
mlx90614BEA
Manufacturer:
JRC
Quantity:
1 600
Part Number:
mlx90614ESF
Manufacturer:
AH
Quantity:
25 000
Part Number:
mlx90614ESF
Manufacturer:
MELEXIS/迈来芯
Quantity:
20 000
Part Number:
mlx90614ESF-AAA
Manufacturer:
CYPRESS
Quantity:
625
Part Number:
mlx90614ESF-AAA-000-TU
Manufacturer:
MELEXIS/迈来芯
Quantity:
20 000
Part Number:
mlx90614ESF-ACC-000-TU
Manufacturer:
MELEXIS/迈来芯
Quantity:
20 000
Part Number:
mlx90614ESF-ACF-000-TU
Manufacturer:
INF
Quantity:
1 430
Part Number:
mlx90614ESF-BAA
Manufacturer:
Melexis Inc
Quantity:
1 875
Part Number:
mlx90614ESF-BAA-000-TU
Manufacturer:
MELEXIS/迈来芯
Quantity:
20 000
Part Number:
mlx90614ESF-BAA-000-TU
0
Part Number:
mlx90614ESF-BBA
Manufacturer:
MELEXIS/迈来芯
Quantity:
20 000
Part Number:
mlx90614ESF-BCC-000-TU
0
8.4.7 Sleep Mode
The MLX90614 can enter in Sleep Mode via the command “Enter SLEEP mode” sent via the SMBus
interface. This mode is not available for the 5V supply version. To limit the current consumption to 2.5uA
(typical), the SCL pin should be kept low during sleep. MLX90614 goes back into power-up default mode (via
POR reset) by setting SCL pin high and then PWM/SDA pin low for at least t
configured for PWM (EN_PWM is high), the PWM interface will be selected after awakening and if
PWM control [2], PPODB is 1 the MLX90614 will output a PWM pulse train with push-pull output.
8.4.7.1 Enter Sleep Mode
8.4.7.2 Exit from Sleep Mode
3901090614
Rev 003
PWM/SDA
SCL
PWM/SDA
SCL
Figure 10: Exit Sleep Mode
command
Sleep
Figure 9: Enter sleep
Sleep
Page 17 of 40
condition
Awake
Stop
Infra Red Thermometer in TO-39
Stop
tDDq
MLX90614 family
Normal
Sleep
Single and Dual Zone
DDq
=80ms. If EEPROM is
Data Sheet
03/Oct/2007

Related parts for mlx90614