uzz9000 NXP Semiconductors, uzz9000 Datasheet

no-image

uzz9000

Manufacturer Part Number
uzz9000
Description
Sensor Conditioning Electronics
Manufacturer
NXP Semiconductors
Datasheet
Product specification
Supersedes data of 2000 May 19
DATA SHEET
UZZ9000
Sensor Conditioning Electronic
DISCRETE SEMICONDUCTORS
2000 Nov 27

Related parts for uzz9000

uzz9000 Summary of contents

Page 1

... DISCRETE SEMICONDUCTORS DATA SHEET UZZ9000 Sensor Conditioning Electronic Product specification Supersedes data of 2000 May 19 2000 Nov 27 ...

Page 2

... Since today’s applications typically require analog output signals (e.g. potentiometers), the resulting signal is transferred back to the analog domain. The UZZ9000 enables the user to set both the angle range and the zero point offset. These ranges are set by external voltage dividers. QUICK REFERENCE DATA ...

Page 3

... SYMBOL R thermal resistance from junction to ambient th j-a ESD SENSITIVITY SYMBOL PARAMETER ESD ESD sensitivity 2000 Nov 27 CONDITIONS 125 to 150 C; max 200 hours PARAMETER CONDITIONS human body model machine model 3 Product specification UZZ9000 MIN. MAX. UNIT +150 ...

Page 4

... V sensor voltage LM FUNCTIONAL DESCRIPTION The UZZ9000 is a mixed signal IC for angle measurement systems. The UZZ9000 has been designed for the double sensor KMZ41. It combines two analog signals (sine and cosine) into a linear output signal. The analog measurement signals on the IC input are converted to digital data by two ADC’ ...

Page 5

... Fig.2. Without any zero point offset, the ramp-up starts at mechanical When using a KMZ41 sensor, the maximum angular range 180 . For the UZZ9000, smaller angular ranges can be set. In this case, 2 becomes smaller than 180 and the output curve is clipped at this position. The ...

Page 6

... Fig.3 Output curve for different angular ranges including a zero point offset. 2000 Nov ˚ ˚ to 180 as Fig.2 Output curve for different angular ranges off 0 ˚ ˚ to 180 as 6 Product specification UZZ9000 180 360 MHB695 180 360 MHB696 ...

Page 7

... Zero point offset setting To adjust the zero point offset or to set external voltage has to be applied to the UZZ9000 at pin 14 (VOFFIN). The function is similar to that described 2000 Nov 27 previously. After reset the voltage is read, converted into the digital domain and then stored until another reset state occurs ...

Page 8

... DATA_CLK frequency How to enter the trim mode The status bits to be transmitted to the UZZ9000 are shown in Table 4. Note that a complete protocol has to be sent before normal operation can be resumed. The trim mode can also be exited by resetting the device. After entering one of the trim modes and provided there is a dynamic input signal, a square wave output is visible at the terminal T (pin 22) ...

Page 9

... V disconnected not necessary to connect an output load to the UZZ9000. After recovering from short circuit to ground or supply voltage, the chip returns undamaged to the normal operation mode. There is no time limitation ...

Page 10

... Philips Semiconductors Sensor Conditioning Electronic Table 5 System delay and update rates of the UZZ9000 PARAMETER system delay (time elapsed until 95% of the final value is reached) max. signal frequency < 200 MHz transients (step response) measurement update rate (room temperature) 150 C 2000 Nov 27 MIN ...

Page 11

... REFERENCES JEDEC EIAJ MS-013 detail 1.1 1.1 1.4 0.25 0.25 0.4 1.0 0.043 0.043 0.01 0.055 0.01 0.016 0.039 EUROPEAN PROJECTION Product specification UZZ9000 SOT137 ( 0.9 0.1 0 0.035 0.004 0.016 ISSUE DATE 97-05-22 99-12-27 ...

Page 12

... Product specification UZZ9000 (1) These products are not Philips Semiconductors ...

Page 13

... Philips Semiconductors Sensor Conditioning Electronic 2000 Nov 27 NOTES 13 Product specification UZZ9000 ...

Page 14

... Philips Semiconductors Sensor Conditioning Electronic 2000 Nov 27 NOTES 14 Product specification UZZ9000 ...

Page 15

... Philips Semiconductors Sensor Conditioning Electronic 2000 Nov 27 NOTES 15 Product specification UZZ9000 ...

Page 16

Philips Semiconductors – a worldwide company Argentina: see South America Australia: 3 Figtree Drive, HOMEBUSH, NSW 2140, Tel. +61 2 9704 8141, Fax. +61 2 9704 8139 Austria: Computerstr. 6, A-1101 WIEN, P.O. Box 213, Tel. + 101 ...

Related keywords