SY10/100E137 Micrel Semiconductor, SY10/100E137 Datasheet

no-image

SY10/100E137

Manufacturer Part Number
SY10/100E137
Description
Manufacturer
Micrel Semiconductor
Datasheet
CLK, CLK
Q
A_Start
EN
MR
V
V
FEATURES
PIN NAMES
1.8GHz min. count frequency
Extended 100E V
Synchronous and asynchronous enable pins
Differential clock input and data output pins
V
Asynchronous Master Reset
Internal 75K input pull-down resistors
Available in 28-pin PLCC packge
PIN CONFIGURATION
BB
CCO
0
BB
–Q
1
, EN
A_Start
Pin
7
output for single-ended use
, Q
CLK
2
EN
EN
CLK
V
V
0
EE
BB
–Q
1
2
7
2
3
4
26
27
28
1
EE
25 24 23 22
5
Differential Clock Inputs
Differential Q Outputs
Asynchronous Enable Input
Synchronous Enable Inputs
Asynchronous Master Reset
Switching Reference Output
V
range of –4.2V to –5.5V
6
CC
TOP VIEW
7
to Output
PLCC
J28-1
8
21 20 19
9
Function
10 11
18
17
16
15
14
13
12
Q
Q
Q
V
Q
Q
Q
CC
4
3
4
3
2
2
8-BIT RIPPLE
COUNTER
1
counters. The two least significant bits were designed
with very fast edge rates, while the more significant bits
maintain standard ECLinPS output edge rates. This allows
the counters to operate at very high frequencies, while
maintaining a moderate power dissipation level.
clock generation, as well as for counters in high-
performance ATE time measurement boards.
available to maximize the device's flexibility for various
applications. The asynchronous enable input, A_Start,
when asserted, enables the counter while overriding any
synchronous enable signals. The E137 features XOR'ed
enable inputs, EN
the CLK input. When only one synchronous enable is
asserted, the counter becomes disabled on the next CLK
transition. All outputs remain in the previous state poised
for the other synchronous enable or A_Start to be
asserted in order to re-enable the counter.
both synchronous enables causes the counter to become
enabled on the next transition of the CLK. EN
and CLK edges are coincident. Sufficient delay has been
inserted in the CLK path (to compensate for the XOR
gate delay and the internal D-flip-flop set-up time) to
ensure that the synchronous enable signal is clocked
correctly; hence, the counter is disabled.
the V
CLK input signal. If a single-ended signal is to be used,
the V
bypassed to ground via a 0.01 F capacitor. V
only source/sink 0.5mA; therefore, it should be used as
a switching reference for the E137 only.
pull-down resistor. Therefore, do not leave the differential
CLK inputs open. Doing so causes the current source
transistor of the input clock gate to become saturated,
thus upsetting the internal bias regulators and
jeopardizing the stability of the device.
an all zero state upon assertion.
DESCRIPTION
The SY10/100E137 are very high speed binary ripple
The devices are ideally suited for multiple frequency
Both asynchronous and synchronous enables are
The E137 can also be driven single-endedly utilizing
All input pins left open will be pulled LOW via an input
The asynchronous Master Reset resets the counter to
BB
BB
pin should be connected to the CLK input and
output supply as the voltage reference for the
1
and EN
2
, which are synchronous to
Rev.: C
Issue Date: February, 1998
SY100E137
SY10E137
1
FINAL
Amendment: /1
Asserting
(or EN
BB
can
2
)

Related parts for SY10/100E137

SY10/100E137 Summary of contents

Page 1

... CC 8-BIT RIPPLE COUNTER DESCRIPTION The SY10/100E137 are very high speed binary ripple counters. The two least significant bits were designed with very fast edge rates, while the more significant bits maintain standard ECLinPS output edge rates. This allows the counters to operate at very high frequencies, while maintaining a moderate power dissipation level ...

Page 2

Micrel BLOCK DIAGRAM A_Start R EN1 D Q EN2 Q CLK CLK CLK CLK MR VBB SEQUENTIAL TRUTH TABLE Function EN EN A_Start 1 2 Reset X X Count Stop ...

Page 3

Micrel DC ELECTRICAL CHARACTERISTICS (Min (Max.); Symbol Parameter V Output Reference BB Voltage 10E 100E I Input HIGH Current IH I Power Supply EE Current 10E 100E AC ELECTRICAL CHARACTERISTICS ...

Page 4

Micrel 28 LEAD PLCC (J28-1) MICREL-SYNERGY 3250 SCOTT BOULEVARD SANTA CLARA CA 95054 USA + 1 (408) 980-9191 TEL This information is believed to be accurate and reliable, however no responsibility is assumed by Micrel for its use nor for ...