at27bv4096 ATMEL Corporation, at27bv4096 Datasheet - Page 10

no-image

at27bv4096

Manufacturer Part Number
at27bv4096
Description
4-megabit 256k X 16 Unregulated Battery-voltage High-speed Otp Eprom
Manufacturer
ATMEL Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
at27bv4096-12JC
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
at27bv4096-12JI
Manufacturer:
LUCENT
Quantity:
5
Part Number:
at27bv4096-12JI
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
at27bv4096-12JI
Manufacturer:
ATMEI
Quantity:
20 000
Part Number:
at27bv4096-12JU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
at27bv4096-12VI
Manufacturer:
Atmel
Quantity:
5
Part Number:
at27bv4096-12VU
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
at27bv4096-15JC
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
at27bv4096-15JC
Manufacturer:
ALTERA
0
Part Number:
at27bv4096-15JC
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
at27bv4096-15JI
Manufacturer:
ATMEL
Quantity:
4
Part Number:
at27bv4096-15VI
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
18. Rapid Programming Algorithm
10
AT27BV4096
A 50 µs CE pulse width is used to program. The address is set to the first location. V
to 6.5V and V
without verification. Then a verification/reprogramming loop is executed for each address. In the
event a word fails to pass verification, up to 10 successive 50
cation after each pulse. If the word fails to verify after 10 pulses have been applied, the part is
considered failed. After the word verifies properly, the next address is selected until all have
been checked. V
pared with the original data to determine if the device passes or fails.
PP
is raised to 13.0V. Each address is first programmed with one 50 µs CE pulse
PP
INCREMENT ADDRESS
INCREMENT ADDRESS
is then lowered to 5.0V and V
YES
NO
ADDR.?
LAST
PROGRAM ONE 50 µS PULSE
PROGRAM ONE 50 µS PULSE
PASS
ADDR = FIRST LOCATION
ADDR = FIRST LOCATION
NO
TO ORIGINAL
PASS
ALL WORDS
VPP = 13.0V
VCC = 6.5V
VCC = 5.0V
COMPARE
VPP = 5.0V
PASSED
VERIFY
DEVICE
ADDR.?
START
WORD
DATA
X = 0
LAST
YES
CC
to 5.0V. All words are read again and com-
FAIL
FAIL
µ
s pulses are applied with a verifi-
INCREMENT X
NO
DEVICE
FAILED
X = 10?
YES
0640E–EPROM–8/07
CC
is raised