h7cx-a114-n Omron Corporation, h7cx-a114-n Datasheet - Page 44

no-image

h7cx-a114-n

Manufacturer Part Number
h7cx-a114-n
Description
Multifunction Counter/tachometer
Manufacturer
Omron Corporation
Datasheet
44
H7CX-R@-N
Change to Function Setting Mode.
Step2
Run mode
Power ON
Output ON
count alarm set
value/monitor
value
Output
hysteresis
(HYS)
Set value
upper limit
(SL-H)
Key
protect
level
(KYPT)
Decimal point
position
(DP)
Auto-zero
time
(AUTO0)
Output OFF
delay
(OFFD)
Prescale value
(PSCL)
Peak/bottom
hold
enabled
(DHLD)
Averaging
method
(AUGT)
Startup
time
(STMR)
3 s min.
3 s min.
*1
setting mode
*1
*2
Function
The characters displayed in reverse video are the default settings.
• Set the decimal point position using the U Key.
Note: The measurement value after prescaling is set.
Note: Not displayed in AMD-compatible mode.
• Set the averaging method using the U Key.
Note: Not displayed in AMD-compatible mode.
(No decimal point) (One digit after
• Set each digit using the individual U Key.
• Set each digit using the individual U Key.
• Enable or disable peak/bottom hold using the U Key.
• Set the output hysteresis using the U Key.
• Set each digit using the individual U Key.
• Set each digit using the individual U Key.
• Set the key protect level using the U Key.
• Set each digit using the individual U Key.
(Disabled)
(0.1 s)
(0.0 s)
(0.001)
(SMP)
(0.00 s)
smp
kp-1
off
(KP-1)
0.00
(0)
(1)
0
1
(99.9 s)
(Enabled)
(999.9 s)
(MV)
(1.000)
mv
on
(19.99 s)
999999
(999999)
99999
(99999)
kp-2
(KP-2)
19.99
For details on operations in run mode, refer to page page 47.
*1 If the mode is switched to the function setting mode during operation, operation will
*2 Changes made to settings in function setting mode are enabled for the first time when the
decimal point)
continue.
mode is changed to run mode.
Also, when settings are changed, the counter is reset (measured values initialized and
output turned OFF) on returning to run mode.
(99.999)
kp-3
(KP-3)
(Two digits after
decimal point)
kp-4
(KP-4)
(Three digits after
kp-5
(KP-5)
decimal point)
kp-6
(KP-6)
*1 Set each digit using the individual U Key.
Procedure for Models Other than “-R11W@” Models
Procedure for “-R11W@” Models
kp-7
(KP-7)
Output
ON count
alarm set
value
Output
ON count
monitor
value
Output 1
(OUT1) ON
count alarm
set value
Output 1
(OUT1) ON
count
monitor
value
Output 2
(OUT2) ON
count alarm
set value
Output 2
(OUT2) ON
count
monitor
value
Note: The monitor value is only
(0 1000 times)
Note: The monitor value is only
(0 1000 times)
(0 1000 times)
Note: The monitor value is only
displayed. It cannot be set.
displayed. It cannot be set.
displayed. It cannot be set.
0
0
0
(9999 1000 times)
(9999 1000 times)
(9999 1000 times)
9999
9999
9999

Related parts for h7cx-a114-n