ta1360ang TOSHIBA Semiconductor CORPORATION, ta1360ang Datasheet - Page 77

no-image

ta1360ang

Manufacturer Part Number
ta1360ang
Description
Ycbcr/ypbpr Signal And Sync Processor For Digital Tv, Progressive Scan Tv And Double Scan Tv
Manufacturer
TOSHIBA Semiconductor CORPORATION
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TA1360ANG
Manufacturer:
TOSHIBA
Quantity:
1 000
Part Number:
TA1360ANG
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
Note
T03
T04
T05
T06
T07
T08
No.
Characteristics
Unicolor
adjustment
characteristic
Brightness
adjustment
characteristic
White peak
slice level
Black peak
slice level
RGB output
S/N
Halftone
characteristic
SW3
A
A
C
C
C
A
SW4
B
B
B
B
B
B
SW5
B
B
B
B
B
B
SW33
A
A
A
A
A
A
Test Conditions
SW Mode
SW34
A
A
A
A
A
A
SW35
A
A
A
A
A
A
SW37
A
A
A
A
A
A
SW38
A
A
A
A
A
A
SW39
A
A
A
A
A
A
77
1.
2.
3.
1.
2.
1.
2.
3.
4.
1.
2.
1.
2.
3.
4.
1.
2.
3.
4.
5.
6.
7.
Input signal 1 (f
Change unicolor data to maximum (7F), center (40), and minimum (00) and measure pin 43
picture period amplitude, V
Calculate amplitude ratio of V
Input signal 2 from pin 3 and adjust pin 43 picture period output amplitude to 1 Vp-p.
Change brightness data to maximum (7F), center (80), and minimum (00) and measure pin
43 voltages, V
Set subcontrast to maximum.
Apply external power supply to pin 3 and gradually increase voltage from 5.8 V.
When picture period of pin 43 is clipped, measure pin 43 picture period amplitude voltage,
V
Change subaddress (0C) data to (FC) and repeat the steps 1 to 3 above. (V
Apply external power supply to pin 3 and gradually decrease voltage from 5.8 V.
When picture periods are clipped, measure pins 41, 42, and 43 voltage, V
Adjust brightness data so that picture period voltage of pin 41 is 2.4 V.
Set color data to minimum.
Measure noise levels n41-, n42-, and n43-Vp-p in picture period of pin 41, 42, and 43 with an
oscilloscope.
Calculate S/N.
Input signal 1 (f
Measure pin 41 picture period amplitude v41A.
Apply 1.5 V to pin 52 from external power supply.
Measure pin 41 picture period amplitude v41B
Calculate the following equation. G
Stop applying voltage to pin 52. Set subaddress (1A) to data (E2) and measure pin 41-picture
period amplitude, v41C.
Calculate the following equation. G
wps1
.
N
N
N
41
42
43
= −20 × og
= −20 × og
= −20 × og
brMAX
0
0
= 100 kHz, picture period amplitude = 0.2 Vp-p) from pin 3.
= 100 kHz, picture period amplitude 0.2 Vp-p) from pin 3.
l
l
l
, V
brCNT
[2.3/(0.2 × n41)]
[2.3/(0.2 × n42)]
[2.3/(0.2 × n43)]
uMAX
, and V
uMAX
, V
uCNT
and V
brMIN
HT1
HT2
Test Method
, and V
= v41B/v41A
= v41C/v41A
uMIN
respectively.
in decibels (∆V
uMIN
respectively.
u
)
TA1360ANG
bps
wps2
.
2005-08-18
)

Related parts for ta1360ang