s10112-512q Hamamatsu Photonics, K.K.,, s10112-512q Datasheet - Page 5

no-image

s10112-512q

Manufacturer Part Number
s10112-512q
Description
Cmos Linear Image Sensors
Manufacturer
Hamamatsu Photonics, K.K.,
Datasheet
Start pulse (ST) interval
INT pulse rise and fall times
INT pulse - clock pulse timing
Clock pulse - INT pulse timing
Start pulse rise and fall times
Clock pulse duty ratio
Clock pulse rise and fall times
Clock pulse - start pulse timing
Start pulse - clock pulse timing
Timing chart
Enlarged view
(available term)
Allow CLK pulse transition from “high” to “low” only one time while ST pulse is “high”.
Integration time is determined by the interval between start pulses.
Only the switching noise component is output from the Dummy Video line.
Do not use the Dummy Video output during integration readout.
The INT signal is not needed between EOS and the rising edge of the next ST signal.
Active Video
Active Video (available term)
Parameter
CMOS linear image sensors
EOS
CLK
CLK
INT
INT
ST
ST
tf(CLK)
S1011*-128
S1011*-256
S1011*-512
S1011*-1024
t(ST-CLK)
tr(ST)
1st
1/f(CLK)
2nd 3rd
tr(CLK)
4th
tpi(ST), integration time
tf(CLK), tr(CLK)
tr(INT), tf(INT)
1st
tf(ST), tr(ST)
t(INT-CLK)
t(CLK-INT)
T(ST-CLK)
t(CLK-ST)
t(CLK-ST)
t(INT-CLK)
tf(ST)
Symbol
tpi(ST)
tr(INT)
-
2nd
Last pixel
t(CLK-INT)
3rd
tf(INT)
1026/f(CLK)
130/f(CLK)
258/f(CLK)
514/f(CLK)
INT should be "high" when not reading pixels.
Min.
30
30
40
20
20
0
0
0
4th
S10111 to S10114 series
1st 2nd 3rd 4th
5th
Typ.
20
20
50
20
-
-
-
-
-
-
-
-
1 / [2 × f(CLK)]
1 / [2 × f(CLK)]
Max.
30
30
60
30
-
-
-
-
-
-
KMPDC0249ED
Unit
ns
ns
ns
ns
%
ns
ns
ns
s
5