s10127 Hamamatsu Photonics, K.K.,, s10127 Datasheet
s10127
Related parts for s10127
s10127 Summary of contents
Page 1
... S8982 delivers low dark current when operated in MPP (Multi Pinned-Phase) mode. S10127 is an easy-to-use X-ray imaging module using S8982, with added functions such as a cable assembly and X-ray trigger circuit. S10127 is low cost type for S8981-02 and adapted both AC and DC X-ray sources. ...
Page 2
... S8982, S10127 CCD area image sensor ...
Page 3
... Device structure P1V’ P2V’ TG’ SS ...... OS OD ...... RD RG’ OG SG’ P1H’ P2H’ PD CCD area image sensor X-RAY IRRADIATION MONITORING PHOTODIODE KMPDC0163EA S8982, S10127 3 ...
Page 4
... SG’ 100 RG RG’ GND Timing chart PRE-INTEGRATION PERIOD 15 AC X-RAY EXPOSURE (Trigger X-RAY EXPOSURE (Trigger Trigger B (S10127) * P1V 17 P2V P1H P2H OUT P2V, TG P1H P2H OUT *15: Trigger A (S8982) is the same as AC/DC X-ray exposure form. *16: Low active trigger pulse *17: TG terminal can be short-circuited to P2V terminal ...
Page 5
... Dimensional outlines (unit: mm) 35.5 ± 0.5 3.0 GOS FILM 31.5 3.6 30.0 C1.0 CCD area image sensor S8982 ACTIVE AREA 1.0 1.9 GOS FILM 19.5 CCD CHIP S8982, S10127 CONNECTOR ALUMINA SUBSTRATE KMPDA0187EA 5 ...
Page 6
... The shield of cable and the shroud of MDR connector are electrically connected each other. They are short-circuited, so there is no electrical contact to any other positions. CCD sensor ( (4 ×) R2.5 3.5 6 CCD area image sensor S10127 FERRITE CABLE 2000 PIN No 38.7 6.1 32.6 13.6 30.0 5.2 1.3 R2.0 R2.0 (30 degrees) S8982, S10127 CCD SENSOR SHROUD 10.2 7.4 4.0 5.1 CABLE ACTIVE AREA 1.0 4.0 KMPDA0189EA KMPDA0190EA ...
Page 7
... CCD area image sensor Information furnished by HAMAMATSU is believed to be reliable. However, no responsibility is assumed for possible inaccuracies or omissions. Specifications are subject to change without notice. No patent rights are granted to any of the circuits described herein. ©2006 Hamamatsu Photonics K.K. S8982, S10127 Cat. No. KMPD1083E03 Sept. 2006 DN ...