CPT-DIN ETC2 [List of Unclassifed Manufacturers], CPT-DIN Datasheet - Page 2

no-image

CPT-DIN

Manufacturer Part Number
CPT-DIN
Description
Energy Management Compact Power Transducer
Manufacturer
ETC2 [List of Unclassifed Manufacturers]
Datasheet
CPT-DIN
Input specifications (cont.)
Additional errors
Temperature drift
Sampling rate
Measurement refresh time
Output Specifications
Analogue Outputs
Digital outputs
Measurement format
2
Reactive power
Active energy
Reactive energy
Frequency
Humidity
Frequency
Instantaneous variables
Energies
Ripple
Number of outputs
Accuracy (@ 25°C±5°C, R.H. ≤60%) ±0.3% FS
Range
Scaling factor:
Response time
Total temperature drift
Load:
Insulation
Pulse
Pulse duration
Alarm
Number of outputs
Type
Number of outputs
Alarm modes
20 mADC
10 VDC
±(2%RDG+3DGT)
Class 2 according to EN62053-21
(I start up: 10mA)
Class 3 according to EN62053-23
(I start up: 10mA)
±0.1Hz (48 to 62Hz)
≤0.3% FS, 60% to 90% RH
≤0.3% FS (45 to 48Hz and 62
to 65Hz)
≤ 200ppm/°C
1600 samples/s @ 50Hz
1900 samples/s @ 60Hz
200ms
Up to 3
0 to 20mA or 0 to 10 VDC
Programmable within the
whole range of retransmis-
sion; it allows the retrans-
mission management of all
values from: 0 and
20 mA, 0 and 10VDC
≤ 400 ms typical
(filter excluded)
≤ 1%, according to
IEC 60688-1, EN 60688-1
≤ 500 ppm/°C
≤ 350 Ω
≥ 10KΩ
By means of optocouplers,
See table “Insulation
between inputs and outputs”
Up to 2
Programmable from 0.01 to 500
pulses per kWh/kvarh (total
counters)
Outputs connectable to the
total energy meters
(Wh/varh)
according to EN62053-31
up to 2, independent
Up alarm, down alarm, in
window alarm, out window
alarm.
Start-up deactivation func-
tion at power-on for all
kinds of alarm. All of them
connectable to all variables
(see the table “List of the
variables that can be con-
nected to”)
(serial communication)
4 DGT, max indication 9999
8+1 DGT, max indication
999 999 99.9
≥ 100ms <120msec (ON),
≥ 120ms (OFF)
Specifications are subject to change without notice
Input impedance
Frequency
Note
Static outputs
Relay outputs
Reed relay output
Measurements
Overload protection
Hourcounter
Type
Coupling type
Crest factor
400/690V
120/208V
Current
Continuos voltage/current
For 500ms: voltage/current
Purpose
Signal
Insulation
Purpose
Type
Insulation
Purpose
Type
Switching voltage
Switching current
Carry current
Mechanical life
Insulation
Set-point adjustment
Hysteresis
On-time delay
Output status
Min. response time
L-L
L-L
(AV5)
(AV6)
Current, voltage, power,
power factor, frequency
TRMS measurement of
distorted waves.
Direct
< 3, max 10A peak
1.6 MΩ ±5%
1.6 MΩ ±5%
≤ 0.01Ω
45 to 65 Hz
(max values)
AV5: 460V
AV6: 145V
AV5: 800V
AV6: 240V
From 0 to 100% of the
retransmitted scale
from 0 to full scale
0 to 255s
Selectable; normally
de-energized and normally
energized
≤400ms, filters excluded and
with alarm delay: “0 s”
The 2 digital outputs
can also work as one pulse
output and one alarm
output.
For alarm outputs or for pulse
outputs
V
V
By means of optocouplers,
See table “Insulation
between inputs and outputs”
For alarm outputs or for pulse
outputs
Relay, SPST type
AC 1-5A @ 250VAC
DC 12-5A @ 24VDC
AC 15-1.5A @ 250VAC
DC 13-1.5A @ 24VDC
See table “Insulation
between inputs and outputs”
For alarm output or for pulse
output
Reed relay, SPST type NO
Max 200VDC, peak AC resistive
Max 0.5ADC, peak AC resistive
Max 2ADC, peak AC resistive
300x10
See table “Insulation
between inputs and outputs”
5+2 DGT, max indication
9 999 9.99
ON
OFF
1.2 VDC/ max. 100 mA
30 VDC max.
6
operations (1V/10mA)
CPT-DINADS110706
LN
LN
LN
LN
/800V
/250V
/1380V
/416V
LL
LL
LL
LL
/6A
/6A
/36A
/36A