CPT1000 RHOPOINT [RHOPOINT COMPONENTS], CPT1000 Datasheet

no-image

CPT1000

Manufacturer Part Number
CPT1000
Description
Platinum Temperature Sensor SMD 1206 CPT 1000
Manufacturer
RHOPOINT [RHOPOINT COMPONENTS]
Datasheet
Revision
07/01
© UST Umweltsensortechnik GmbH 2006
Subject to alterations for this information and technological changes
UST Umweltsensortechnik GmbH
Dieselstr. 2, 98716 Geschwenda, Germany
Technical Data
Resistance at 0° C
Temperature coefficient
(0° C up to 100° C)
Tolerance class to DIN EN 60751
Operating temperature range
Measurement current (DC)
at 25 ° C
Maximal permissible peak current
(DC) at 25 ° C
Insulation resistance
Self-heating at 0 ° C
Thermal response time
Resistance value
(Class B) at
Maximal Resistance Change
at UCT 250 h
Functional performance
according to DIN EN 60751
Picture 1: Resistance and temperature tolerances of CPT 1000 B
Temperature range of -50 ° C up to 0 ° C:
R
Temperature range of 0° C up to 150° C:
R
Tolerance class B to DIN EN 60751:
∆t = ± (0.3 + 0.005 · | t |)
Flowing water (v = 0.2 m/s)
Flowing air (v = 1 m/s)
t
t
= R
= R
± 5,0
± 4,0
± 3,0
± 2,0
± 1,0
± 0,0
o
o
-50
· (1 + A · t + B · t
· (1 + A · t + B · t
Class B [ ]
Class B [°C]
0
Platinum Temperature Sensor SMD 1206 CPT 1000
Temperature [°C]
2
2
)
0 ° C
100 ° C
+ C · (t – 100 ° C) · t
50
1000
3.85 · 10
B
-50 ° C up to 150 ° C
0.1 mA
0.3 mA
> 10 M
< 0.4 K / mW
T
T
T
T
1000.00
1385.10
< 0.1 %
100
0.5
0.9
0.5
0.9
= 0.5 s
= 4 s
= 10 s
= 0.2 s
Phone +49 36205 713-0
Fax +49 36205 713-10
-3
3
150
)
K
± 1.2
± 3.0
-1
± 2,5
± 2,0
± 1,5
± 1,0
± 0,5
± 0,0
Construction
Specification
Technology
Advanced thin-film-technology (ceramic carrier with
a structured platinum layer, covered with a
passivating layer)
Conformity
2002/95/EC Restriction of the use of Hazardous
Substances Directive (RoHS)
Dimensions [mm]
Whereby:
R
R
t … Temperature [° C]
∆t … Permissible temperature deviation at t [° C]
A = 3.9083 · 10
B = - 5.775 · 10
C = - 4.183 · 10
Fields of application
• Industrial electronics
• Automotive electronics
• Energy and environmental engineering
Ordering information
Please use the following code:
Code CPT 1000
Other classes of
info@umweltsensortechnik.de
www.umweltsensortechnik.de
t
o
… Resistance [ ] at temperature t
… Resistance [ ] at 0 ° C
Type
0.5 ± 0.25
0.5 ± 0.25
-3
0.5 ± 0.25
0.5 ± 0.25
0.5 ± 0.25
-7
-12
accuracy available on request
° C
° C
3 + 0.35
3 + 0.35
° C
- 0.1
- 0.1
-1
-2
accuracy
Class of
-4
B
Protective layer
Protective layer
Solder joint
Solder joint
Ceramic carrier
Ceramic carrier
Construction Temperature
SMD 1206
SMD 1206
DIN EN 60751
Made in Germany
range [° C]
-50/150

Related parts for CPT1000

Related keywords