Specification for LC band pass filter:
1. General
1.1. Package:
1.2.
1.3.
1.4.
1.5.
2.
2.1.
2.2.
2.2.1. Centre frequency fc at +25°C:
2.2.2. Bandwidth between 3 dB - frequencies:
2.2.3. Ripple in pass band ( peak to peak ):
2.2.4. Insertion loss:
2.3.
2.3.1. fc ± 7.0 MHz
2.3.2. fc ± 8.0 MHz
2.3.3. fc ± 9.5 MHz
2.3.4. fc ± 11.0 MHz
2.3.5. Alternate attenuation
2.4.
2.5.
2.6.
3.
4.
______________________________________________________________________________________
Edited by:
Type name:
Number of poles:
Operating temperature range:
Storage temperature range:
Electric values
Nominal centre frequency fo:
Pass band
( measured on smallest attenuation in pass band )
Stop band
Terminating impedance ( input and output ):
3-rd order intermodulation products measured at 108.1 MHz:
test tones 107.7 MHz / 107.3 MHz, power level -24 dBm:
test tones 97.9 MHz / 103.0 MHz, power level -1.9 dBm:
test tones 98.0 MHz / 87.9 MHz, power level +4.1 dBm:
Maximum input power level:
Marking:
Environment conditions:
date: __________________________ name: ____________________________
IN
VECTRON
601083-001 OR-002
LC 113.0-10.0/06
L C 1 1 3 . 0 - 1 0 . 0 / 0 6
LC 113.0-10.0/06
6
-40°C to +85°C
-55°C to +125°C
113.0 MHz
113.0 MHz ± 500 kHz
> fc ± 5.0 MHz
< 1.0 dB
≤ 5.0 dB
+25dBm / +30dBm ( working / non-damaged )
Corresponding to Vectron MIL Standard 202
YYWW
≥ 10 dB
≥ 20 dB
≥ 30 dB
≥ 40 dB
≥ 80 dB
50 Ω // 0 pF
-110 dBm ( 86 dB down from test tones )
-110 dBm ( 86 dB down from test tones )
-110 dBm ( 86 dB down from test tones )
OUT
30 August 2010

Related parts for lc1130-100-06