PCF8576 Philips Semiconductors, PCF8576 Datasheet - Page 20

no-image

PCF8576

Manufacturer Part Number
PCF8576
Description
Universal LCD driver for low multiplex rates
Manufacturer
Philips Semiconductors
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PCF8576CF
Manufacturer:
PHILTPS
Quantity:
20 000
Part Number:
PCF8576CH
Manufacturer:
PHILIPS
Quantity:
22 164
Part Number:
PCF8576CH/1
Manufacturer:
NXP
Quantity:
12 000
Part Number:
PCF8576CH/1
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Part Number:
PCF8576CH/1,118
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Part Number:
PCF8576CH/1,157
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Part Number:
PCF8576CH/F1
Manufacturer:
PHI
Quantity:
10
Part Number:
PCF8576CH/F1
Manufacturer:
PHILIPS/飞利浦
Quantity:
20 000
Part Number:
PCF8576CHL
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Part Number:
PCF8576CHL/1
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Part Number:
PCF8576CHL/1
0
Part Number:
PCF8576CHL/1,118
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Part Number:
PCF8576CHL/1,157
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Part Number:
PCF8576CHL1
Manufacturer:
NICHICON
Quantity:
5 503
Part Number:
PCF8576CT
Manufacturer:
NXP
Quantity:
3
Part Number:
PCF8576CT/1
0
Company:
Part Number:
PCF8576CT/1
Quantity:
15 000
Philips Semiconductors
After acknowledgement, one or more command bytes (m)
follow which define the status of the addressed PCF8576s.
The last command byte is tagged with a cleared most
significant bit, the continuation bit C. The command bytes
are also acknowledged by all addressed PCF8576s on the
bus.
After the last command byte, a series of display data bytes
(n) may follow. These display bytes are stored in the
display RAM at the address specified by the data pointer
and the subaddress counter. Both data pointer and
subaddress counter are automatically updated and the
data is directed to the intended PCF8576 device.
The acknowledgement after each byte is made only by the
(A0, A1 and A2) addressed PCF8576. After the last display
byte, the I
1998 Feb 06
handbook, full pagewidth
Universal LCD driver for low multiplex
rates
2
C-bus master issues a STOP condition (P).
SDA
SCL
START condition
SDA
SCL
S
Fig.13 Definition of START and STOP conditions.
data valid
data line
stable;
Fig.12 Bit transfer.
20
allowed
change
of data
7.8
The command decoder identifies command bytes that
arrive on the I
continuation bit C in their most significant bit position
(Fig.17). When this bit is set, it indicates that the next byte
of the transfer to arrive will also represent a command.
If this bit is reset, it indicates the last command byte of the
transfer. Further bytes will be regarded as display data.
The five commands available to the PCF8576 are defined
in Table 5.
Command decoder
2
C-bus. All available commands carry a
STOP condition
MBA607
P
MBC622
SDA
SCL
Product specification
PCF8576

Related parts for PCF8576