X90100MI XICOR [Xicor Inc.], X90100MI Datasheet - Page 3

no-image

X90100MI

Manufacturer Part Number
X90100MI
Description
NV Electronically Programmable Capacitor
Manufacturer
XICOR [Xicor Inc.]
Datasheet
ABSOLUTE MAXIMUM RATINGS
Temperature under bias ....................–65 ° C to +135 ° C
Storage temperature .........................–65°C to +150°C
Voltage on CS, INC, U/D, C
∆ V = |V
Lead temperature (soldering 10 seconds)..........300°C
CAPACITOR CHARACTERISTICS (Vcc=+5V, T
Notes: (1) Absolute linearity is used to determine actual capacitance versus expected capacitance = C
REV 1.4.7 9/8/03
C
Symbol
C
C
M
V
TOTAL
TOTAL
DNL
V
V
TC
INL
∆ C
∆ C
Q
with respect to V
Cm
CC
Cp
(2) Relative linearity is a measure of the error in step size between settings = C
(3) lsb = least significant bit = C
(4) Typical values are for T
(5) This parameter is not 100% tested
CP
1
–V
CM
Absolute accuracy
C
C
Capacitance increments
Capacitance range
Capacitance at Code=0
Capacitance at Code=31
Quality factor
Resolution
Absolute linearity error
Relative linearity error
C
Supply Voltage
p
m
TOTAL
| ..................................................... 5V
terminal voltage
terminal voltage
SS
Temperature Coefficient
........................... –1V to +7V
Parameter
P
(5)
A
, and
= 25°C and nominal supply voltage.
TOT
/31.
(2)
(1)
(5)
A
www.xicor.com
=25°C, single ended mode, C
Min.
2.7
0
0
COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only; the functional operation of
the device (at these or any other conditions above
those listed in the operational sections of this specifi-
cation) is not implied. Exposure to absolute maximum
rating conditions for extended periods may affect
device reliability.
Typ
±0.15
±0.15
0.23
14.5
±15
±50
7.5
7
7
5
(4)
Limits
.
(n+1)
Max.
V
V
5.5
CC
CC
—[C
(n)
ppm/°C Differential Mode
+ Ml] = ±0.15 Ml.
Unit
M
bits
lsb
lsb
pF
pF
pF
pF
%
V
V
V
= 0V, unless otherwise stated.)
(n)
(actual) — C
f=315 MHz
Test Conditions/Notes
(n)
(expected) = ±0.15 Ml.
X90100
3 of 10

Related parts for X90100MI