RT9711 RICHTEK [Richtek Technology Corporation], RT9711 Datasheet - Page 4

no-image

RT9711

Manufacturer Part Number
RT9711
Description
80m?, 1.5A High-Side Power Switches with Flag
Manufacturer
RICHTEK [Richtek Technology Corporation]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
RT9711
Manufacturer:
RICHTEK/立锜
Quantity:
20 000
Part Number:
RT9711AGB
Manufacturer:
RICHTEK
Quantity:
5
Part Number:
RT9711AGB
Manufacturer:
RICHTEK/立錡
Quantity:
20 000
Part Number:
RT9711AGB
0
Company:
Part Number:
RT9711AGB
Quantity:
5 900
Part Number:
RT9711AGBG
Manufacturer:
RICHTEK/立锜
Quantity:
20 000
Part Number:
RT9711AGF
Manufacturer:
RICHTEK/立锜
Quantity:
20 000
Company:
Part Number:
RT9711APBG
Quantity:
3 000
Part Number:
RT9711APF
Manufacturer:
TOSHIBA
Quantity:
1 037
Part Number:
RT9711APF
Manufacturer:
RICHTEK/立锜
Quantity:
20 000
Part Number:
RT9711BGB
Manufacturer:
RICHTEK
Quantity:
3 609
Part Number:
RT9711BPF
Manufacturer:
RICHTEK
Quantity:
1 325
Part Number:
RT9711BPS(RICKTEK)
Quantity:
484
RT9711
Note 1. Stresses listed as the above "Absolute Maximum Ratings" may cause permanent damage to the device. These are for
Note 2. Devices are ESD sensitive. Handling precaution recommended.
Note 3. The device is not guaranteed to function outside its operating conditions.
Note 4. The FLAG delay time is input voltage dependent, see“ Typical Operating Characteristics” graph for further details.
Note 5. θ
www.richtek.com
4
FLAG Delay Time
Under-Voltage Lockout
Under-Voltage Hysteresis
Thermal Shutdown Protection
Thermal Shutdown Hysteresis
stress ratings. Functional operation of the device at these or any other conditions beyond those indicated in the
operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended
periods may remain possibility to affect device reliability.
JEDEC 51-3 thermal measurement standard.
JA
is measured in the natural convection at T
Parameter
(Note 4)
V
ΔV
T
ΔT
Symbol
t
D
SD
UVLO
SD
UVLO
A
Preliminary
From fault condition to FLG
V
V
= 25°C on a low effective single layer thermal conductivity test board of
IN
IN
increasing
decreasing
Test Conditions
Min
1.3
--
--
5
--
DS9711-04 March 2007
Typ
130
1.7
0.1
12
20
Max
20
--
--
--
--
Units
ms
°C
°C
V
V