LM70CILD-5 National Semiconductor, LM70CILD-5 Datasheet - Page 8

no-image

LM70CILD-5

Manufacturer Part Number
LM70CILD-5
Description
SPI/MICROWIRE 10-Bit plus Sign Digital Temperature Sensor
Manufacturer
National Semiconductor
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LM70CILD-5/NOPB
Manufacturer:
TI/德州仪器
Quantity:
20 000
www.national.com
Typical Performance Characteristics
Average Power-On Reset Voltage
vs Temperature
1.0 Functional Description
The LM70 temperature sensor incorporates a band-gap type
temperature sensor and 10-bit plus sign
(Delta-Sigma Analog-to-Digital Converter). Compatibility of
the LM70’s three wire serial interface with SPI and MI-
CROWIRE allows simple communications with common mi-
crocontrollers and processors. Shutdown mode can be used
to optimize current drain for different applications. A manu-
facture’s ID register identifies the LM70 as National Semi-
conductor product.
1.1 POWER UP AND POWER DOWN
The LM70 always powers up in a known state. The power up
default condition is continuous conversion mode. Immediatly
after power up the LM70 will output an erroneous code until
the first temperature conversion has completed.
When the supply voltage is less than about 1.6V (typical),
the LM70 is considered powered down. As the supply volt-
age rises above the nominal 1.6V power up threshold, the in-
ternal registers are reset to the power up default state de-
scribed above.
1.2 SERIAL BUS INTERFACE
The LM70 operates as a slave and is compatible with SPI or
MICROWIRE bus specifications. Data is clocked out on the
falling edge of the serial clock (SC), while data is clocked in
on the rising edge of SC. A complete transmit/receive com-
munication will consist of 32 serial clocks. The first 16 clocks
comprise the transmit phase of communication, while the
second 16 clocks are the receive phase.
When CS is high SI/O will be in TRISTATE
should be initiated by taking chip select (CS) low. This
should not be done when SC is changing from a low to high
state. Once CS is low the serial I/O pin (SI/O) will transmit
the first bit of data. The master can then read this bit with the
rising edge of SC. The remainder of the data will be clocked
out by the falling edge of SC. Once the 14 bits of data (one
sign bit, ten temperature bits and 3 high bits) are transmitted
the SI/O line will go into TRI-STATE. CS can be taken high at
any time during the transmit phase. If CS is brought low in
the middle of a conversion the LM70 will complete the con-
version and the output shift register will be updated after CS
is brought back high.
The receive phase of a communication starts after 16 SC pe-
riods. CS can remain low for 32 SC cycles. The LM70 will
read the data available on the SI/O line on the rising edge of
the serial clock. Input data is to an 8-bit shift register. The
DS101223-23
®
. Communication
Static Supply Current vs
Temperature
ADC
8
part will detect the last eight bits shifted into the register. The
receive phase can last up to 16 SC periods. All ones must be
shifted in order to place the part into shutdown. A zero in any
location will take the LM70 out of shutdown. The following
codes only should be transmitted to the LM70:
• 00 hex (normal operation)
• 01 hex (normal operation)
• 03 hex (normal operation)
• 07 hex (normal operation)
• 0F hex (normal operation)
• 1F hex (normal operation)
• 3F hex(normal operation)
• 7F hex(normal operation)
• FF hex (Shutdown, transmit manufacturer’s ID)
any others may place the part into a Test Mode. Test Modes
are used by National Semiconductor to thoroughly test the
function of the LM70 during production testing. Only eight
bits have been defined above since only the last eight trans-
mitted, before CS is taken HIGH, are detected by the LM70
The following communication can be used to determine the
Manufacturer’s/Device ID and then immediately place the
part into continuous conversion mode. With CS continuously
low:
• Read 16 bits of temperature data
• Write 16 bits of data commanding shutdown
• Read 16 bits of Manufacture’s/Device ID data
• Write 8 to 16 bits of data commanding Conversion Mode
• Take CS HIGH.
Note that 250 ms will have to pass for a conversion to com-
plete before the LM70 actually transmits temperature data.
.
DS101223-21
Temperature Error
DS101223-22

Related parts for LM70CILD-5