VI-AIM VICOR Corporation, VI-AIM Datasheet

no-image

VI-AIM

Manufacturer Part Number
VI-AIM
Description
Universal AC Input Front End Module
Manufacturer
VICOR Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
VI-AIM-A1/S
Manufacturer:
VICOR
Quantity:
492
Part Number:
VI-AIM-C1
Manufacturer:
VICOR
Quantity:
78
Part Number:
VI-AIM-C1
Manufacturer:
AEG
Quantity:
134
Part Number:
VI-AIM-C1
Manufacturer:
VICOR
Quantity:
20 000
Part Number:
VI-AIM-C1
Quantity:
77
Part Number:
VI-AIM-C1-01
Manufacturer:
VICOR
Quantity:
78
Part Number:
VI-AIM-C1-01
Manufacturer:
VICOR
Quantity:
492
Part Number:
VI-AIM-E1
Manufacturer:
VICOR
Quantity:
20 000
Part Number:
VI-AIM-E1
Quantity:
77
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
45
Product Highlights
The AIM (Alternating Input Module)
is an AC front-end module which
interfaces directly with worldwide
AC mains. The AIM provides line
rectification, EMI/RFI filtering,
transient protection and inrush
limiting in a half brick package
measuring 2.28" x 2.4" x 0.5".
The AIM is used in conjunction with
Vicor VI-200 or VI-J00 DC-DC
converters to realize a universal AC
input, high density, low profile
switching power supply with outputs
from 1-95Vdc and a total power rating
up to 200W. An external capacitor is
used to satisfy system hold up
requirements. Internal EMI filtering
meets EN55022 and FCC part 15,
class A emissions limits.
VI-AIM Selection Chart
Features
• Universal Input: 85 to 264Vac
• Output Power: 250W
• Operating Temperature: 100°C
• Efficiency: 97%
• Integral EMI Filtering
• Input Transient Protection
• Inrush Limiting
• CE Marked
VI-AIM-E1
VI-AIM-C1
VI-LAIM-E1
VI-LAIM-C1
Input Voltage
180-264Vac
85-132Vac
85-264Vac
Mega Module packaging option
VI-AIM
PC Mount
Compatible DC-DC
VI-AIM-I1
VI-AIM-M1
VI-LAIM-I1
VI-LAIM-M1
Converter
VI-X5X
VI-X6X
VI-X7X
Set your site on VICOR at www.vicorpower.com
VI-AIM Specifications
(typical at T
Product Grade Specifications
Parameter
AC Line Input
Output Voltage
Efficiency
Output Power
Holdup Time
Maximum Value of
Holdup Capacitance
Conducted EMI/RFI
Inrush Current
Transient Surge Withstand
Normal Mode
Dielectric Withstand
Thermal Resistance
Safety Approvals
Size
Weight
*Dependent upon input range of compatible DC-DC converter.
Parameter
Storage Temperature
Operating Temperature
(Baseplate)
Data Sheet
VI-AIM
Universal AC Input Front End Module
Common Mode
Input to Output
Input/Output to Baseplate
BP
= 25°C, nominal line, 75% load unless otherwise specified)
AIM, Universal AC Input Front End Module
-20°C to +105°C
-10°C to +100°C
E-Grade
Specifications
85Vac to 264Vac*
47 Hz to 440 Hz
120-373 Vdc
97%
250W
Application specific
1200 µF
VDE 0871/FCC Part 15, Class A
EN 55022, Class A
<40A at Peak Line (264 Vrms)
1.2/50 µS, 2 kV Pulse, 2 Joules
0 to 360 Degree Phase Angle
1.2/50 µS, 1 kV Pulse, 2 Joules
0 to 360 Degree Phase Angle
None
1,500 V rms
0.4°C/Watt
UL 1950, CSA 22.2-950, EN 60950
2.28" x 2.4" x 0.5"
(57,9 x 61,0 x 12,7)
packages available
3.0 Ounces (85 Grams)
-40°C to +105°C
-25°C to +100°C
C-Grade
-55°C to +105°C
-40°C to +100°C
I-Grade
57,9 x 61,0 x 12,7 mm
No strapping; no
damage below low line
Peak of AC line
Delivered to converter(s)
A function of external
capacitance and power
With compatible DC-DC
converter modules. External
0.47µF capacitor required.
EN61000-4-5
IEC 801-5
With external MOV
Provided by DC-DC converter
Baseplate-to-sink
Mega Module,
SlimMOD and FinMOD
Shown actual size:
2.28 x 2.4 x 0.5 in
Rev. 2.1
Remarks
-65°C to +105°C
-55°C to +100°C
M-Grade
Page 1 of 2

Related parts for VI-AIM

VI-AIM Summary of contents

Page 1

... An external capacitor is used to satisfy system hold up requirements. Internal EMI filtering meets EN55022 and FCC part 15, class A emissions limits. VI-AIM Selection Chart PC Mount VI-AIM-E1 VI-AIM-I1 VI-AIM-C1 VI-AIM-M1 Mega Module packaging option ...

Page 2

... VI-AIM Connection Diagram, Typical Application Universal N/C Z1 .47 F N/C L2/N * See Vicor's Applications Manual, page 12-2, Selecting Capacitors for AIM Modules. Z1: MOV P/N 03040 Fuse 1: 6.3A/250V (IEC 5X20 mm) Buss GDB-6.3 or 7A/250V (3AG 1/4" 1/4") Littlefuse 314-007 Fuse 2: For VI-X7X-XX — Buss PC-Tron 2.5A (250V) For VI-X6X-XX — ...