SX1231 SEMTECH [Semtech Corporation], SX1231 Datasheet - Page 28

no-image

SX1231

Manufacturer Part Number
SX1231
Description
Low Power Integrated UHF Transceiver
Manufacturer
SEMTECH [Semtech Corporation]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SX1231HIMLTRT
Manufacturer:
SEMTECH/美国升特
Quantity:
20 000
Part Number:
SX1231HIMLTRT
0
Company:
Part Number:
SX1231HIMLTRT
Quantity:
24 000
Part Number:
SX1231IMLTRT
Manufacturer:
ATMEL
Quantity:
1 200
Part Number:
SX1231IMLTRT
Manufacturer:
SEMTECHCORPORATION
Quantity:
20 000
Part Number:
SX1231ITSTRT
Manufacturer:
SEMTECH/美国升特
Quantity:
20 000
Part Number:
SX1231MLTRT
Manufacturer:
SEMTECH/美国升特
Quantity:
20 000
In peak threshold mode the comparison threshold level is the peak value of the RSSI, reduced by 6dB. In the absence of
an input signal, or during the reception of a logical "0", the acquired peak value is decremented by one
OokPeakThreshStep every OokPeakThreshDec period.
When the RSSI output is null for a long time (for instance after a long string of "0" received, or if no transmitter is present),
the peak threshold level will continue falling until it reaches the "Floor Threshold", programmed in OokFixedThresh.
The default settings of the OOK demodulator lead to the performance stated in the electrical specification. However, in
applications in which sudden signal drops are awaited during a reception, the three parameters should be optimized
accordingly.
Note
3.5.11.1. Optimizing the Floor Threshold
OokFixedThresh determines the sensitivity of the OOK receiver, as it sets the comparison threshold for weak input signals
(i.e. those close to the noise floor). Significant sensitivity improvements can be generated if configured correctly.
Note that the noise floor of the receiver at the demodulator input depends on:
It is therefore important to note that the setting of OokFixedThresh will be application dependant. The following procedure
is recommended to optimize OokFixedThresh.
Rev 2 - Nov 2009
ADVANCED COMMUNICATIONS & SENSING
The noise figure of the receiver.
The gain of the receive chain from antenna to base band.
The matching - including SAW filter if any.
The bandwidth of the channel filters.
For a correct operation of the peak threshold mode of the OOK demodulator, set 0x0c at address 0x6e.
Figure 10. Floor Threshold Optimization
OokFixedThresh
Increment
Page 28
Adjust Bit Rate, Channel filter BW
Default OokFixedThresh setting
Set SX1231 in OOK Rx mode
Monitor DIO2/DATA pin
Optimization complete
Continuous Mode
No input signal
Glitch activity
on DATA ?
DATASHEET
www.semtech.com
SX1231

Related parts for SX1231