SSD1854U ETC [List of Unclassifed Manufacturers], SSD1854U Datasheet - Page 28

no-image

SSD1854U

Manufacturer Part Number
SSD1854U
Description
LCD Segment / Common Driver with Controller CMOS
Manufacturer
ETC [List of Unclassifed Manufacturers]
Datasheet
60
61
62
63
64~67
68~80
81
82~87
88
89
8A
8B
8C
8D
8E
8F
90~97
98~9F
A0~A1
A2~A3
A4~A5
23
SSD1854
Series
0110 0000
0A
0110 0001
A
0110 0010
0B
0110 0011
B
0110 01B
1000 0001
XXC
1000 1000
WB
1000 1001
WD
1000 1010
LB
1000 1011
LD
1000 1100
DB
1000 1101
DD
1000 1110
BB
1000 1111
BD
1001 0 FRC PWM1 PWM0
1010 000S
1010 010E
7
7
A
B
3
3
6
6
3
3
3
3
LB
3
LD
3
DB
BB
BD
A
B
DD
6
6
WB
WD
5
A
B
5
5
C
2
2
A
B
2
5
5
2
2
LB
LD
2
BB
DB
BD
A
B
4
DD
2
4
4
2
WB
WD
C
4
4
1
A
B
1
LB
1
1
LD
1
1
A
B
3
1
BB
3
3
B
DB
BD
Rev 1.0
08/2002
DD
C
0
0
A
B
1
3
3
1
0
0
WB
A
B
WD
0
2
2
2
0
LA
0
0
C
A
B
LC
0
2
2
BA
DA
BC
A
B
DC
1
1
1
0
3
0
A
B
C
3
1
1
LA
WA
LC
WC
3
A
B
3
3
0
0
0
BA
3
DA
BC
DC
0
0
2
2
LA
3
LC
2
3
WA
2
2
BA
WC
2
DA
BC
1
DC
1
LA
LC
1
2
1
1
2
BA
WA
DA
1
BC
WC
0
DC
0
0
0
0
1
1
0
WA
WC
0
0
Set Upper
Window Corner
a
Set Upper
Window Corner
a
Set Lower
Window Corner
b
Set Lower
Window Corner
b
Set DC-DC
Converter Factor
Reserved
Set Contrast
Control Register
Reserved
Set White Mode,
Frame 2
Set White Mode,
Frame 4
Set Light Gray
Mode, Frame 2
& 1
Set Light Gray
Mode, Frame 4
& 3
Set Dark Gray
Mode, Frame 2
& 1
Set Dark Gray
Mode, Frame 4
& 3
Set Black Mode,
Frame 2
Set Black Mode,
Frame 4
Set PWM and
FRC
Reserved
Set Segment Re-
map
Reserved
Set Entire
Display On/Off
x
y
x
y
st
rd
st
rd
nd
th
nd
th
& 3
& 3
& 1
& 1
rd
rd
st
st
nd
th
nd
th
The second command sets the first column of the scroll
window. It is set to 0 after POR.
The second command sets the first row of the scroll
window. It is set to 0 after POR.
The second command sets the last column of the scroll
window. It is set to 0 after POR.
The second command sets the last row of the scroll
window. It is set to 0 after POR.
Set the DC-DC multiplying factor from 3X to 5X
according to B
B
00: 3X (POR)
01: 4X
10: 5X
11: 5X
Reserved
The second command sets one of the 64 contrast
levels. The darkness increase as the contrast level
increase.
Reserved
Grey
commands used to specify the contrast levels for the
gray scale, 4 levels available. The relationship between
gray mode and data in RAM is as follow:
Set PWM and FRC for gray-scale operation.
FRC = 0: 4-frames (POR)
FRC = 1: 3-frames
PWM = 00: 9-levels (POR)
PWM = 01: 9-levels
PWM = 10: 12-levels
PWM = 11: 15-levels
Reserved
S
S
Reserved
E
E
1
0
0
0
0
B
=0: column address 00H is mapped to SEG0 (POR)
=1: column address 7FH is mapped to SEG0
=0: Normal display (display according to RAM
=1: All pixels are ON regardless of the RAM
0
:
contents, POR)
contents
palette
Byte
1
0
0
1
1
1
st
B
Memory
Content
programming.
0
.
Byte
2
0
1
0
1
nd
Gray Mode
Light gray
Dark gray
These
White
Black
SOLOMON
are
two-byte

Related parts for SSD1854U