LPT100-M EMERSON-NETWORKPOWER [Emerson Network Power], LPT100-M Datasheet

no-image

LPT100-M

Manufacturer Part Number
LPT100-M
Description
130 Watts Medical and ITE safeties
Manufacturer
EMERSON-NETWORKPOWER [Emerson Network Power]
Datasheet
Safety
• TUV 60950, 60601-1
• UL
• CSA
• NEMKO
• AUSTEL
• CB
• CE
Total Power:
Input Voltage:
# of Outputs:
Special Features
• Medical and ITE safeties
• Active power factor correction
• 2” x 4” footprint
• Less than 1U high
• EN61000-3-2 compliant
• Remote sense
• Power fail
• Adjustable main output
• Built-in Class B EMI filter
• Overvoltage protection
• Overload protection
• Thermal overload protection
• LPX50 enclosure kit available
LPT100-M Series
130 Watts
60950, 60601-1
60950, 60601-1
60950, 60601-1
Certificate & report
Mark (LVD)
60950, 60601-1
80 - 130 Watts
90 - 264 Vac
Triple
Electrical Specifications
Input
Input range:
Frequency:
Inrush current:
Efficiency:
EMI/RFI:
Safety ground
leakage current:
Output
Maximum power:
Adjustment range:
Hold-up time:
Overload protection:
Overvoltage protection: 15 - 35% above nominal output
Logical Control
Power failure:
Remote sense:
90 - 264 Vac; 127 - 300 Vdc
47 - 63 Hz
50 A max., cold start @ 25 °C
82% typical at full load
FCC Class B conducted; CISPR22 Class B conducted;
EN55022 Class B conducted; VDE0878PT3 Class B conducted
2 75 µA @ 50/60 Hz, 264 Vac input
80 W for convection;
130 W with 200 LFM forced air
All outputs adjustable - 40%, +10%, except for +24V output on LPT104-M
which will be -10%, +20% and 3.3 V output on the LPT101-M +10%, -15%
10 ms @ 130 W load, 120 Vac input
Short circuit protection on all outputs. Case overload
protected @ 110 - 160% above rating for V1 & V2, 110-190% for V3
Active LowTTL logic signal goes high 100 - 500 msec after main output; it
goes low at least 6 msec before loss of regulation
C ompensates for 0.5 V lead drop min. Will operate without remote sense
connected. Reverse connection protected.
Embedded Power for
Business-Critical Continuity
Rev. 10.9.09_141
LPT100-M Series
1 of 3

Related parts for LPT100-M

LPT100-M Summary of contents

Page 1

... Overload protection: Short circuit protection on all outputs. Case overload protected @ 110 - 160% above rating for V1 & V2, 110-190% for V3 Overvoltage protection 35% above nominal output Logical Control Power failure: Active LowTTL logic signal goes high 100 - 500 msec after main output; it goes low at least 6 msec before loss of regulation Remote sense: C ompensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected. Embedded Power for Business-Critical Continuity Rev. 10.9.09_141 LPT100-M Series ...

Page 2

... Mechanical Drawing GND PIN 1 (LIVE) PIN 3 (NEUTRAL) SK1 Output Voltage Adjust Pots SK3 SK2 Mounting Hole ø 0.16” [4.0] 4 Places Max. Screw Head Diameter .22” (5.6) Output Voltage Adjust Pots 0.197” (5.0) Minimum Standoff height Embedded Power for Business-Critical Continuity Rev. 10.9.09_141 LPT100-M Series  of 3 ...

Page 3

... Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Emerson Network Power. The global leader in enabling business-critical continuity. AC Power Connectivity DC Power Embedded Computing Embedded Power Monitoring Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection EmersonNetworkPower.com Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2009 Emerson Electric Co. Rev. 10.9.09_141 LPT100-M Series ...

Related keywords