MPB80 POWER-ONE [Power-One], MPB80 Datasheet

no-image

MPB80

Manufacturer Part Number
MPB80
Description
Power Factor Correction (PFC) Meets EN61000-3-2
Manufacturer
POWER-ONE [Power-One]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MPB80-1024
Manufacturer:
POWERONE
Quantity:
1 000
Part Number:
MPB80-1048
Manufacturer:
LAMBDA
Quantity:
1 000
SINGLE OUTPUT MODEL SELECTION CHART –
NOTES:
DUAL AND TRIPLE OUTPUT MODEL SELECTION CHART –
MPB80-2000
MPB80-3000
MPB80-3300
NOTES:
The MPB80 combines high density power and other standard features
usually found in premium power systems. The low-profile package
neatly fits 1U height constraints in an industry-standard 3" X 5"
footprint. This Power Factor Corrected (PFC), multiple output
FEATURES
• Power Factor Correction (PFC) Meets EN61000-3-2
• Low-Profile Height Fits 1U Constraints
• High 3.3V and 5V Current Capabilities Available
• CE Marked to Low Voltage Directive
• Autoranging AC Input, 85-264 VAC
• Overvoltage Protection on the Main Output
MPB80-1012
MPB80-1024
MPB80-1048
MODEL
MODEL
NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc.
TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
VOLTAGE
OUTPUT
VOLTAGE
OUTPUT
ADJUSTMENT
ADJUSTMENT
RANGE
RANGE
COOLED CURRENT
CONVECTION COOLED
OUTPUT CURRENT
CONVECTION
UP TO 72W CONVECTION COOLED, UP TO 100W FORCED AIR COOLED (300 LFM)
MPB80 SERIES
FORCED AIR
CURRENT
OUTPUT CURRENT
FORCED AIR
1
UP TO 63W CONVECTION COOLED, UP TO 80W FORCED AIR COOLED (300 LFM)
product line features overvoltage and overcurrent protection. In
addition to UL, CSA, and TÜV, regulatory agency compliances
include the CE Marking and harmonic compliance to EN61000-3-2.
REGULATION
LINE
REGULATION
LINE
REGULATION
TOTAL
REGULATION
LOAD
RIPPLE & NOISE
mV (NOTE 1)
RIPPLE & NOISE
%p-p (NOTE 1)
INITIAL SETTING
ACCURACY
INITIAL SETTING
ACCURACY

Related parts for MPB80

MPB80 Summary of contents

Page 1

... The MPB80 combines high density power and other standard features usually found in premium power systems. The low-profile package neatly fits 1U height constraints in an industry-standard 3" X 5" footprint. This Power Factor Corrected (PFC), multiple output FEATURES • Power Factor Correction (PFC) Meets EN61000-3-2 • ...

Page 2

... INPUT SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION OUTPUT SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION INTERFACE SIGNALS AND INTERNAL PROTECTION PARAMETER CONDITIONS/DESCRIPTION MPB80 SERIES 2 MIN NOM MAX UNITS MIN NOM MAX UNITS MIN NOM MAX UNITS ...

Page 3

... SAFETY, REGULATORY, AND EMI SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION ENVIRONMENTAL SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION MPB80 SERIES 3 MIN NOM MAX UNITS MIN NOM MAX UNITS ...

Page 4

... OVERALL SIZE: 5.00" x 3.00" x 1.40" (127.0mm x 76.2mm x 35.6mm) COMPONENT HEIGHT: 1.26" (32.0mm) WEIGHT: 0.8 LBS (0.36 kg MPB80-2000 MPB80-3000 MPB80 SERIES . . . . J2 MPB80-3300 MPB80-10XX ...